基于视频的性能指标评估乳突切除术中运动效率
A Video-based Performance Metric to Assess Efficiency of Motion in Mastoidectomy.
文献信息
| PMID | 43073186 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Obinna I Nwosu |
| 作者单位 | Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear, Boston, MA. |
| 期刊 | Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology |
| SCI 分区 | Q2 |
| IF | 1.9 |
| 研究类型 | AI/ML · 临床 |
| 所属专科 | 耳科 |
中文摘要
目的: 研究一种整合钻头路径长度与骨去除量的新型视频指标——运动效率(EoM),并评估其在乳突切除术模拟中的结构效度。
研究设计: 试点验证研究。
地点: 外科模拟实验室。
参与者: 七名受训者(住院医师和专科培训医师)实施皮质乳突切除术。
干预: 参与者在三个3D打印颞骨模型上实施乳突切除术,分别代表正常解剖、低位鼓室盖和硬化型乳突,顺序随机。
主要结局指标: EoM,定义为估计腔体积除以总钻头路径长度;最终产品性能采用改良Welling量表评估。
结果: EoM在不同解剖条件间存在显著差异,硬化型乳突较正常解剖观察到更低值(P=0.04)。正常与低位鼓室盖模型间未观察到显著差异(P=0.79)。EoM与最终产品评分呈适度正相关(r=0.37)。
结论: EoM提供了一种与任务相关的手术效率测量,捕捉了努力与骨去除之间的关系。基于与其他变量关系的效度证据得到支持,因为该指标能够区分某些预期在钻孔难度上存在差异的解剖条件。
英文摘要
OBJECTIVE: To study a novel video-based metric integrating drill path length and bone removal, efficiency of motion (EoM), and to assess its construct validity in mastoidectomy simulation.
STUDY DESIGN: Pilot validation study.
SETTING: Surgical simulation laboratory.
PARTICIPANTS: Seven trainees (residents and fellows) performing cortical mastoidectomies.
INTERVENTIONS: Participants performed mastoidectomies on three 3D-printed temporal bone models representing normal anatomy, low-lying tegmen, and sclerotic mastoid in randomized order.
MAIN OUTCOME MEASURES: EoM, defined as estimated cavity volume divided by total drill path length; final product performance assessed using the modified Welling Scale.
RESULTS: EoM differed significantly between anatomic conditions, with lower values observed in the sclerotic mastoid compared with normal anatomy (P=0.04). No significant difference was observed between normal and low-lying tegmen models (P=0.79). EoM demonstrated a modest positive correlation with final product scores (r=0.37).
CONCLUSIONS: EoM provides a task-relevant measure of surgical efficiency that captures the relationship between effort and bone removal. Validity evidence based on relations to other variables is supported by the metric's ability to distinguish between some anatomic conditions expected to differ in drilling difficulty.