人工智能在前庭信息检测中的应用:一项批判性叙述性综述
Application of artificial intelligence in vestibular information detection: A critical narrative review.
文献信息
| PMID | 43066930 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Fatemeh Jafarlou |
| 作者单位 | Department of Audiology, Faculty of Rehabilitation, Tabriz University of Medical Sciences, Tabriz, Iran. |
| 期刊 | Journal of vestibular research : equilibrium & orientation |
| SCI 分区 | Q3 |
| IF | 3.1 |
| 研究类型 | 综述 Meta · 临床 |
| 所属专科 | 耳科 |
中文摘要
背景: 眩晕诊断具有高风险,因为单一症状可涵盖从良性位置性眩晕到卒中的范围,而常用的前庭听力学工具(VOG和CDP)存在局限性,包括依赖人工专业经验、成本高以及横断面评估。
目的: 本研究旨在从临床听力学角度批判性评估人工智能在前庭疾病检测中应用的成熟度,以“临床可用准备度”而非仅算法准确性为评判标准。
方法: 按照SANRA指南开展本叙述性批判性综述,基于PubMed/MEDLINE、Scopus、Web of Science和IEEE Xplore(2006—2026年)的检索,并对关键文章的参考文献列表进行手工核查。
结果: 眼震分析在旋转性眼震中F1超过0.97;前庭神经鞘瘤分割报告的合并Dice为0.89(95% CI:0.88—0.90),来自11项研究中56个模型的荟萃分析;CNN/模糊姿势描记法在评估卒中后姿势功能障碍方面显示出97%的准确率。对于ECochG,机器学习已成功应用于耳蜗内记录和基于MRI的内淋巴积水评估,但在本检索范围内,我们未发现将AI应用于click诱发的鼓膜外ECochG波形(特别是总和电位与动作电位(SP/AP)比值)以诊断梅尼埃病内淋巴积水的研究。
结论: AI在该领域的进展不均衡;部分子领域已达到相对成熟,但ECochG-梅尼埃病之间的空白仍处于其他发展良好领域的交汇处。未来优先事项包括多中心标准化、前瞻性验证以及解决可解释性这一尚有争议的作用。本综述仅关注英文来源是其局限性。
英文摘要
Vertigo diagnosis has high stakes, since one symptom spans benign positional vertigo to stroke, while common vestibular audiology tools (VOG and CDP) face limitations including dependence on human expertise, high cost, and cross-sectional evaluation. The aim of this study is to critically assess the maturity of AI applications in the detection of vestibular disorders from a clinical audiology perspective, with the criterion of "readiness for clinical use" rather than just algorithmic accuracy. This narrative critical review was conducted, according to SANRA guidelines, based on searches in PubMed/MEDLINE, Scopus, Web of Science, and IEEE Xplore (2006-2026) and hand-checking of reference lists of key articles. Nystagmus analysis achieved F1 above 0.97 in rotational nystagmus; vestibular schwannoma segmentation reported a pooled Dice of 0.89 (95% CI: 0.88-0.90) with a meta-analysis of 56 models from 11 studies; and CNN/fuzzy posturography demonstrated 97% accuracy in assessing postural dysfunction after stroke. For ECochG, machine learning has been applied successfully to intracochlear recordings and to MRI-based endolymphatic hydrops assessment, but within the scope of this search we identified no study applying AI to click-evoked extratympanic ECochG waveforms, specifically the summating-potential to action-potential (SP/AP) ratio, for the diagnosis of endolymphatic hydrops in Ménière's disease. The progress of AI in this domain is heterogeneous; some subfields have reached relative maturity, but the ECochG-Ménière gap remains at the intersection of otherwise well-developed areas. Future priorities include multicenter standardization, prospective validation, and addressing the debated role of interpretability. The focus on English-language sources is a limitation of this review.