西班牙语与英语AzBio句子测试在双语人工耳蜗使用者中的等效性
Equivalency of Spanish and English AzBio Sentence Testing in Bilingual Cochlear Implant Recipients.
文献信息
| PMID | 43065322 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Sandra Velandia |
| 作者单位 | Department of Otolaryngology - Ear Institute, University of Miami Miller School of Medicine, FL, USA. |
| 期刊 | Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale |
| SCI 分区 | Q1 |
| IF | 2.7 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 耳科 |
中文摘要
重要性: 噪声中言语测试是评估人工耳蜗(CI)结局的核心手段,但其在双语使用者中的有效性仍不明确。语言相关差异可能导致对功能性听力的错误估计。
目的: 确定测试语言和掩蔽语言是否影响双语CI使用者的噪声中言语表现,并评估基于言语的听觉加工测量与非语言听觉加工测量之间的关系。
设计: 采用受试者内比较的试点前瞻性队列研究。
场所: 三级转诊中心。
参与者: 纳入15名成年西班牙语-英语双语CI使用者。所有参与者均表现出两种语言的功能性熟练度。干预/暴露:参与者完成英语AzBio(AzBioE)和西班牙语AzBio(AzBioS)句子测试以及噪声中听力测试(HINT)。AzBioS句子分别与英语嘈杂语(AzBioS[EngB])和西班牙语嘈杂语(AzBioS[SpaB])一起呈现。使用频谱-时间调制波纹测试(SMRT)评估频谱分辨率。
主要结局和测量指标: 主要结局为达到50%句子识别所需的信噪比(SNR50)。次要指标包括心理测量斜率、渐近表现和SMRT波纹密度阈值。
结果: AzBioE的平均SNR50为7.8 dB,AzBioS(SpaB)和AzBioS(EngB)分别为4.8和5.2 dB。与AzBioE相比,西班牙语条件所需的SNR分别低3.0和2.6 dB。西班牙语嘈杂语条件之间未观察到有意义的差异。两种语言中HINT阈值均低于AzBio阈值,英语HINT比西班牙语HINT高7.88 dB。SMRT与AzBioS表现的相关性并不比与AzBioE表现的相关性更强。
结论: 双语CI使用者的噪声中言语表现因测试语言而异,但不因掩蔽语言而异,提示评估语言可能影响临床解读。
相关性: 测试语言影响CI结局测量,并可能导致对表现的高估或低估。临床医生在解读结果时应考虑语言因素,以提高双语患者结局评估的准确性和公平性。
英文摘要
IMPORTANCE: Speech-in-noise tests are central to evaluating cochlear implant (CI) outcomes, yet their validity in bilingual users remains unclear. Language-related differences may lead to misestimation of functional hearing ability.
OBJECTIVE: To determine whether test language and masker language influence speech-in-noise performance in bilingual CI recipients and to evaluate the relationship between speech-based and nonlinguistic measures of auditory processing.
DESIGN: Pilot prospective cohort study with within-subject comparisons.
SETTING: Tertiary referral center.
PARTICIPANTS: Fifteen adult Spanish-English bilingual CI users were enrolled. All participants demonstrated functional proficiency in both languages.Intervention/Exposures:Participants completed English AzBio (AzBioE) and Spanish AzBio (AzBioS) sentence tests and the Hearing in Noise Test (HINT). AzBioS sentences were presented with English babble (AzBioS[EngB]) and Spanish babble (AzBioS[SpaB]). Spectral resolution was assessed using the Spectral-Temporally Modulated Ripple Test (SMRT).
MAIN OUTCOME(S) AND MEASURE(S): The primary outcome was the signal-to-noise ratio (SNR) required to achieve 50% sentence recognition (SNR50). Secondary measures included psychometric slope, asymptotic performance, and SMRT ripple density thresholds.
RESULTS: Mean SNR50 was 7.8 dB for AzBioE and 4.8 and 5.2 dB for AzBioS(SpaB) and AzBioS(EngB), respectively. Compared with AzBioE, the Spanish conditions required lower SNRs by 3.0 and 2.6 dB, respectively. No meaningful differences were observed between Spanish babble conditions. HINT thresholds were lower than AzBio thresholds in both languages, with English HINTexceeding Spanish HINT by 7.88 dB. SMRT was not more strongly associated with AzBioS performance than with AzBioE performance.
CONCLUSIONS: Speech-in-noise performance in bilingual CI users varies by test language but not by masker language, indicating that the language of assessment may influence clinical interpretation.
RELEVANCE: Test language influenced CI outcome measures and may contribute to the over- or underestimation of performance. Clinicians should consider linguistic factors when interpreting results to improve the accuracy and equity of outcome assessment in bilingual patients.