不完全分隔II型人工耳蜗植入后的长期结局:单中心回顾性队列研究
Long-Term Outcomes After Cochlear Implantation in Incomplete Partition Type II: A Single-Center Retrospective Cohort Study.
文献信息
| PMID | 43063350 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Callum Findlay |
| 作者单位 | Faculty of Medicine, University of Southampton. |
| 期刊 | Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology |
| SCI 分区 | Q2 |
| IF | 1.9 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 耳科 |
中文摘要
目的: 描述不完全分隔II型(IP-II)患者人工耳蜗植入(CI)后的长期听力学结局。
研究设计: 回顾性队列研究。
地点: 英国单家人工耳蜗中心。
患者: 32例(47只植入耳);22例(69%)为女性,12例(38%)在植入时为成人,平均随访11年(标准差:7.53)。
干预: 对诊断为IP-II的耳行人工耳蜗植入。
主要结局指标: 计算机断层扫描(CT)和磁共振成像(MRI)上的解剖特征;手术并发症,包括脑脊液(CSF)事件;耳蜗外电极放置;听力学结局,包括听觉能力分级(CAP)、言语可懂度分级(SIR)以及安静和自适应噪声下的Bamford-Kowal-Bench(BKB)句子测试;电极失活;阻抗测量;以及设备使用情况。
结果: 所有耳均接受术前CT;27只(58%)还接受了MRI。31只耳(66%)存在完整的Mondini三联征。14例(30%)发生CSF渗漏,9例(19%)发生CSF喷涌。植入后3年,CAP和SIR评分中位数分别为6(范围:4至7)和4(范围:1至5)。安静下BKB句子评分中位数为正确率91%[四分位距(IQR):1.5],自适应噪声下为5.85 dB SNR(IQR:7.65)。
结论: 在该队列中,IP-II患者的人工耳蜗植入与频繁的CSF漏和变化的听力结局相关,且表现常持续改善至植入后约3年。评定量表(CAP、SIR)和安静下BKB测试不能可靠识别表现较差者,而噪声下自适应BKB测试可以。术前咨询应说明CSF漏的风险以及达到最佳表现所需时间延长。常规结局评估应在适当年龄包括噪声下言语感知测试。
英文摘要
OBJECTIVE: To characterize long-term audiological outcomes after cochlear implantation (CI) in individuals with incomplete partition type II (IP-II).
STUDY DESIGN: Retrospective cohort study.
SETTING: Single UK cochlear implant center.
PATIENTS: Thirty-two individuals (47 implanted ears); 22 (69%) female, 12 (38%) adults at implantation with a mean follow-up of 11 years (SD: 7.53).
INTERVENTION: Cochlear implantation in ears diagnosed with IP-II.
MAIN OUTCOME MEASURES: Anatomic features on computed tomography (CT) and magnetic resonance imaging (MRI); surgical complications including cerebrospinal fluid (CSF) events; extracochlear electrode placement; audiometric outcomes comprising Categories of Auditory Performance (CAP), Speech Intelligibility Rating (SIR), and Bamford-Kowal-Bench (BKB) sentence tests in quiet and adaptive noise; electrode deactivations; impedance measurements; and device usage.
RESULTS: All ears underwent presurgical CT; 27 (58%) also had MRI. The complete Mondini triad was present in 31 ears (66%). CSF ooze occurred in 14 cases (30%) and CSF gusher in 9 (19%). At 3 years post-implantation, median CAP and SIR scores were 6 (range: 4 to 7) and 4 (range: 1 to 5), respectively. Median BKB sentence score in quiet was 91% correct [interquartile range (IQR): 1.5], and 5.85 dB SNR (IQR: 7.65) in adaptive noise.
CONCLUSIONS: In this cohort, cochlear implantation in IP-II was associated with frequent CSF leaks and variable hearing outcomes, with performance often continuing to improve up to around 3 years after implantation. Rating scales (CAP, SIR) and BKB testing in quiet did not reliably identify poorer performers, whereas adaptive BKB testing in noise did. Preoperative counseling should address the risk of CSF leaks and the extended time to peak performance. Routine outcome assessment should include speech-perception testing in noise once at an appropriate age.