耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

机器人辅助电极插入在儿童人工耳蜗植入中的应用:对微创手术及阻抗结果的意义

Robotic-assisted electrode insertion in pediatric cochlear implantation: Implications for soft surgery and impedance outcomes.

临床研究耳科IF 1.7Q2

文献信息

中文摘要

背景: 听力损失是全球最常见的感官障碍,深刻影响认知、语言和社会发育,尤其在儿童期。人工耳蜗植入是助听器无效的重度至极重度感音神经性听力损失的确定性治疗。由于儿童预期寿命长且存在再次植入的可能性,保留耳蜗结构至关重要。电极阵列插入技术是影响结果的关键因素之一,因为手术创伤可能诱发耳蜗内纤维化并降低性能。电阻抗是评估电极-组织相互作用的有效生物标志物。机器人手术被认为有助于实现更精确、更微创的植入。本研究在儿童患者中评估机器人辅助电极插入与手动插入的对比,考察手术时长和阻抗测量值。方法:招募23名年龄12个月至7岁、患有显著双侧听力损失的儿童,分为两组:机器人电极插入组(RobOtol®)和手动电极插入组。在手术全程及第9个月时获取阻抗数据。结果:机器人手术的手术时长延长(148.1 vs. 109.6分钟;p = 0.029),同时插入速度更慢且更均匀(p = 0.0055)。未观察到任何问题。机器人组在术中(p = 0.012)和9个月随访后(p = 0.032)的阻抗值均显著降低。结论:研究结果表明,机器人方法可减轻耳蜗内损伤,营造更有利的生物学环境。尽管手术时长延长,机器人手术可能有助于耳蜗结构保留和长期结果。需要进一步的前瞻性研究来验证这一证据。

英文摘要

Hearing loss is the most prevalent sensory impairment worldwide, profoundly affecting cognitive, linguistic, and social development, particularly throughout childhood. Cochlear implantation is the definitive treatment for severe-to-profound sensorineural hearing loss that does not respond to hearing aids. Cochlear preservation in children is essential because to their extended life expectancy and the possibility of reimplantation. The technique of electrode array insertion is pivotal among the factors affecting outcomes, as surgical trauma may induce intracochlear fibrosis and diminish performance. Electrical impedance serves as an effective biomarker for evaluating electrode-tissue interaction. Robotic surgery has been suggested to facilitate more precise and minimally invasive implantation. This study evaluated robotic-assisted electrode insertion against manual insertion in pediatric patients, examining surgery durations and impedance measurements. Twenty-three children aged 12 months to 7 years with substantial bilateral hearing loss were recruited and categorized into two groups: robotic electrode insertion (RobOtol®) and manual electrode insertion. Impedance data were obtained throughout the operation and at the nine-month mark. Robotic operations exhibited extended surgical durations (148.1 vs. 109.6 min; p = 0.029), alongside a reduced and more uniform insertion velocity (p = 0.0055). No problems were noted. The impedance values were markedly reduced in the robotic group both during the operation (p = 0.012) and after the 9-month follow-up (p = 0.032). The findings indicate that the robotic method diminishes intracochlear injury, fostering a more advantageous biological milieu. Although the surgical duration is extended, robotic surgery may enhance cochlear preservation and long-term outcomes. Additional prospective studies are required to validate this evidence.