目的: 探讨对侧存在残余听力的成人人工耳蜗使用者,在接受基于人工耳蜗与助听器之间无线耳间响度平衡的标准化双模式验配方案后,其噪声下言语感知与音乐感知的纵向变化。
设计: 前瞻性观察性自身对照纵向研究,纳入接受标准化无线响度平衡验配方案的成人双模式人工耳蜗使用者,并在基线以及3、6、9和12个月后重复评估。
研究样本: 12名语后聋成人人工耳蜗使用者(8名男性、4名女性;平均年龄60岁;范围27-80岁),植入耳为重度至极重度听力损失,对侧耳具有可用残余听力。
结果: 标准化无线响度平衡双模式验配方案与双模式条件下持续优于仅人工耳蜗条件的噪声下言语表现相关,并在SRT50衍生的双耳指标上具有优势。双模式条件下的音乐感知系统性更好,尤其在音高和节奏辨别方面,而和声与乐器识别方面的改善更为渐进且变异较大。SSQ评分在12个月随访期间改善,提示日常听觉情境中自报聆听困难减少。
结论: 包含无线耳间响度平衡的标准化双模式验配方案,与对侧存在残余听力的成人人工耳蜗使用者在噪声下言语表现及音乐感知部分维度上具有临床相关性的改善相关。由于未纳入非平衡对照条件,所观察到的获益应解释为优化双模式验配策略的结果,而非无线响度平衡优于其他验配程序的确定性证据。

英文摘要

OBJECTIVE: To investigate longitudinal changes in speech-in-noise and music perception in adult cochlear implant users with a contralateral residual hearing after a standardized bimodal fitting protocol based on wireless interaural loudness balancing between the cochlear implant and hearing aid.
DESIGN: Prospective observational within-subject longitudinal study of adult bimodal cochlear implant users undergoing a standardized wireless loudness-balancing fitting protocol, with repeated assessments at baseline and after 3, 6, 9, and 12 months.
STUDY SAMPLE: Twelve post-lingually deaf adult cochlear implant users (eight men and four women; mean age, 60 years; range, 27-80 years) with severe-to-profound hearing loss in the implanted ear and usable residual hearing in the contralateral ear.
RESULTS: The standardized wireless loudness-balanced bimodal fitting protocol was associated with consistently better speech-in-noise performance in the bimodal condition than in the cochlear implant-only condition, with advantages in SRT50-derived binaural indices. Music perception was systematically better in the bimodal condition, particularly for pitch and rhythm discrimination, with more gradual and variable gains for harmony and instrument recognition. SSQ scores improved over the 12-month follow-up, suggesting reduced self-reported listening difficulty in everyday auditory situations.
CONCLUSIONS: A standardized bimodal fitting protocol incorporating wireless interaural loudness balancing was associated with clinically relevant improvements in speech-in-noise performance and selected dimensions of music perception in adult cochlear implant users with contralateral residual hearing. Because no non-balanced control condition was included, the observed benefits should be interpreted as outcomes of an optimized bimodal fitting strategy rather than as definitive evidence of superiority of wireless loudness balancing over other fitting procedures.