老年人群人工耳蜗的长期使用
Long-Term Use of Cochlear Implants in the Older Adult Population.
文献信息
| PMID | 43052067 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Maya Hatley |
| 作者单位 | Department of Otolaryngology - Head and Neck Surgery, New York University Grossman School of Medicine, New York, NY, USA. |
| 期刊 | Audiology & neuro-otology |
| SCI 分区 | Q3 |
| IF | 1.8 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 耳科 |
中文摘要
目的: 听力损失影响60-70%的老年人,其中约10%可能符合人工耳蜗植入(CI)的条件。尽管老年人的结局良好,但由于合并症发生率较高、皮层可塑性降低和认知功能下降,长期听觉表现仍存在担忧。本研究评估植入时年龄≥60岁成人的10年言语感知结局及潜在中介因素。
方法: 通过回顾性病历审查,识别了2006年至2014年间接受植入、手术时年龄≥60岁且随访≥10年的98例患者。主要结局为10年时安静条件下单侧(仅CI)辅音-核-辅音(CNC)单词评分,同时也在术前及术后1年和5年进行测量。
结果: 植入时平均年龄为70.2岁(标准差[SD]:6.4,范围:60.1-85.3),平均CI使用经验为12.6年(SD:2.5,范围:10.0-20.1)。CNC评分在1年(d:54.2%,q = 31.70,p < 0.001)、5年(d:56.5%,q = 31.8,p < 0.001)和10年(d:60.0%,q = 34.67,p < 0.001)时较术前显著改善,各术后时间点之间无显著差异。植入时年龄≥70岁与<70岁的患者之间CNC评分无显著差异(F(1, 96) = 1.1,p = 0.306)。最近一次就诊时平均每日CI使用时间越长,与所有术后时间点更高的CNC评分相关(r = 0.435-0.595,p < 0.001)。无法独立生活与5年时评分显著较低相关(d = 15.2,p = 0.003)。
结论: 大多数老年CI使用者在植入后10年言语感知结局稳定。表现与植入时年龄无关,但与持续使用设备和独立生活呈正相关。局限性包括部分数据缺失,尤其是术后10年,以及无法评估认知功能对结局的影响。
英文摘要
OBJECTIVE: Hearing loss affects 60-70% of elderly people, with ∼10% of these potentially eligible for cochlear implantation (CI). While outcomes in older adults have been positive, concerns remain regarding long-term auditory performance due to higher incidence of comorbidities, reduced cortical plasticity, and cognitive decline. This study evaluates 10-year speech perception outcomes and potential mediating factors in adults ≥60 years old at implantation.
METHODS: A retrospective chart review identified 98 patients implanted between 2006 and 2014 who were ≥60 years old at surgery with ≥10 years of follow-up. The primary outcome was unilateral (CI-only) Consonant-Nucleus-Consonant (CNC) word scores in quiet at 10 years, also measured preoperatively and at one and 5 years postoperatively.
RESULTS: Mean age at implantation was 70.2 years (standard deviation [SD]: 6.4, range: 60.1-85.3), and mean CI experience was 12.6 years (SD: 2.5, range: 10.0-20.1). CNC scores improved significantly from preoperative levels at one (d: 54.2%, q = 31.70, p < 0.001), five (d: 56.5%, q = 31.8, p < 0.001), and 10 years (d: 60.0%, q = 34.67, p < 0.001), without significant differences among postoperative time points. CNC scores did not differ significantly between patients implanted ≥70 versus <70 years old (F(1, 96) = 1.1, p = 0.306). Greater average daily CI use at most recent appointment correlated with higher CNC scores at all postoperative intervals (r = 0.435-0.595, p < 0.001). Inability to live independently was associated with significantly lower scores at 5 years (d = 15.2, p = 0.003).
CONCLUSION: Speech perception outcomes were stable in most elderly CI users 10 years post-implantation. Performance was not associated with age at implantation but was positively related to consistent device use and independent living. Limitations include some missing data, especially 10 years postoperatively, and inability to assess the impact of cognitive function on outcomes.