比较喉罩Protector与插管型喉罩在成人患者纤维支气管镜引导气管插管难易度中的效果:一项为期1年的基于医院的随机对照试验

Comparison of Laryngeal Mask Airway Protector and Intubating Laryngeal Mask Airway for Ease of Fiber-optic-guided Tracheal Intubation in Adult Patients: A 1-year Hospital-based Randomized Controlled Trial.

临床研究咽喉科IF 1.1Q3

文献信息

中文摘要

背景: 声门上气道装置(SADs)已成为现代气道管理的重要组成部分,尤其在困难气道情形和纤维支气管镜引导气管插管中。插管型喉罩长期被视为气管插管的可靠通道,而LMA Protector™作为一种较新的第二代SAD,具有气道密封改善和胃引流通道等额外优势。关于二者作为纤维支气管镜引导插管通道效能的比较证据仍然有限。
目的: 本研究旨在比较经LMA Protector与插管型LMA实施纤维支气管镜引导气管插管的难易度,并评估通过两种装置使用可弯曲纤维镜所获得的声门视野分级。
材料与方法: 本随机对照试验在Belagavi的KLES Dr. Prabhakar Kore Charitable Hospital and Medical Research Centre进行,为期1年。共纳入68例年龄20-60岁、美国麻醉医师学会(ASA)分级I-III级、在全身麻醉下接受择期手术的患者,并随机分为两组,每组34例。I组使用插管型LMA进行插管,P组使用LMA Protector进行插管。评估参数包括LMA置入所需时间、置入过程中的阻力分级、置入尝试次数、气管插管所需时间、插管尝试次数,以及纤维支气管镜所获得的声门视野分级。
结果: 两组的人口学特征和ASA分级具有可比性。LMA置入平均时间在I组为27.36 ± 2.73秒,在P组为29.17 ± 2.02秒,差异无统计学意义(P = 0.188)。首次尝试LMA置入成功率在I组为91.2%,在P组为88.2%(P = 0.690)。与P组相比,I组的气管插管时间显著更短。两种装置在纤维支气管镜引导插管中均表现出较高的总体成功率和令人满意的声门可视化。
结论: 插管型LMA和LMA Protector均为纤维支气管镜引导气管插管的有效通道,成功率高且置入难易度相当。插管型LMA表现出更短的插管时间,而LMA Protector提供了相当的声门可视化和置入特征。操作者熟悉程度和临床情境仍是设备选择的重要决定因素。

英文摘要

BACKGROUND: Supraglottic airway devices (SADs) have become integral to modern airway management, particularly in difficult airway scenarios and fiber-optic-guided tracheal intubation. The intubating laryngeal mask airway has long been regarded as a reliable conduit for tracheal intubation, whereas the LMA Protector™, a newer second-generation SAD, offers additional advantages including improved airway sealing and gastric drainage channels. Comparative evidence regarding their efficacy as conduits for fiber-optic-guided intubation remains limited.
OBJECTIVES: The objective of this study was to compare the ease of fiber-optic-guided tracheal intubation through the LMA Protector and Intubating LMA and to evaluate the grade of glottic view obtained through both devices using a flexible fibrescope.
MATERIALS AND METHODS: This randomized controlled trial was conducted at KLES Dr. Prabhakar Kore Charitable Hospital and Medical Research Centre, Belagavi, over a period of 1 year. Sixty-eight patients aged 20-60 years belonging to the American Society of Anesthesiologists (ASA) grades I-III and undergoing elective surgeries under general anesthesia were enrolled and randomized into two groups of 34 each. Group I underwent intubation using Intubating LMA, whereas Group P underwent intubation using LMA Protector. Parameters assessed included time taken for LMA insertion, grade of resistance during insertion, number of insertion attempts, time taken for tracheal intubation, number of intubation attempts, and grade of glottic view obtained with fiber-optic bronchoscopy.
RESULTS: The demographic characteristics and ASA grading were comparable between the two groups. Mean time taken for LMA insertion was 27.36 ± 2.73 s in Group I and 29.17 ± 2.02 s in Group P, with no statistically significant difference (P = 0.188). First-attempt LMA insertion success was achieved in 91.2% of Group I and 88.2% of Group P patients (P = 0.690). Tracheal intubation time was significantly shorter in Group I compared to Group P. Both devices demonstrated high overall success rates for fiber-optic-guided intubation and satisfactory glottic visualization.
CONCLUSION: Both the Intubating LMA and LMA Protector were effective conduits for fiber-optic-guided tracheal intubation with high success rates and comparable ease of insertion. The Intubating LMA demonstrated a shorter intubation time, whereas the LMA Protector provided comparable glottic visualization and insertion characteristics. Operator familiarity and clinical context remain important determinants in device selection.