一种用于鼻咽癌个性化自适应放疗的定量触发模型
A quantitative trigger model to enable personalized adaptive radiotherapy in nasopharyngeal carcinoma.
文献信息
| PMID | 43048269 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Xiao-Li Yu |
| 作者单位 | Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in Southern China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China. |
| 期刊 | Therapeutic advances in medical oncology |
| SCI 分区 | Q2 |
| IF | 4.1 |
| 研究类型 | AI/ML · 临床 |
| 所属专科 | 鼻咽癌 |
中文摘要
背景: 自适应放疗(ART)在鼻咽癌(NPC)中的应用日益增多,但最佳触发时机仍未明确。
目的: 本研究开发了一种定量触发模型,整合临床专业经验与治疗过程中的形态学和剂量学变化,以支持个性化、可扩展的ART决策。
设计: 这是一项在中山大学肿瘤防治中心开展的单中心回顾性队列研究。
方法: 2022年至2024年间,纳入60例在整合式ART平台(uRT-linac 506c)上接受治疗的NPC患者。40例在放疗期间至少接受过一次ART的患者构成训练集;以临床医生模拟的ART时机为参考,对原始治疗计划与分次放疗之间的形态学和剂量学参数进行量化、加权并建模。其余20例患者(17例接受ART,3例未接受)作为验证集。
结果: 共分析来自60例患者(40例训练、20例验证)的1,466次扇形束CT扫描。开发了加权触发评分(TS),结合靶区和关键危及器官(腮腺、下颌下腺、甲状腺、脑干、脊髓、视神经、视交叉和颞叶)的体积学评分与剂量学评分。定义了两种触发模式:1)绝对TS ≥65分,或2)TS变化比 ≥1.5(=TS_y × (y - 2)/Σ TS_2:TS_(y-1),其中y = 分次数)。在验证队列中,该模型与临床医生模拟的触发时机高度一致,ROC-AUC分别为0.879(每日)和0.872(每周)。该模型已整合至我们的临床ART平台投入运行使用。
结论: 我们开发并验证了一种透明、定量的触发模型,整合临床专业经验与量化的体积学/剂量学变化及结构优先级,以实现NPC的个体化ART决策。该模型支持具有可调阈值的自动化、实时ART触发,可适应不同影像频率,并可根据机构实践进行定制。然而,在广泛临床采用之前,仍需要进行多中心或前瞻性验证。
英文摘要
BACKGROUND: Adaptive radiotherapy (ART) is increasingly used for nasopharyngeal carcinoma (NPC), yet optimal triggers remain undefined.
OBJECTIVES: This study developed a quantitative trigger model integrating clinical expertise with morphological and dosimetric changes during treatment to support personalized, scalable ART decision-making.
DESIGN: This was a single-center, retrospective cohort study conducted at Sun Yat-sen University Cancer Center.
METHODS: Between 2022 and 2024, 60 NPC patients treated on an integrated ART platform (uRT-linac 506c) were enrolled. Forty patients who underwent ART at least once during radiotherapy constituted the training set; morphological and dosimetric parameters between the original treatment plan and fractional radiotherapy were quantified, weighted, and modeled using clinician-simulated ART timing as the reference. The remaining 20 patients (17 with ART and 3 without) served as the validation set.
RESULTS: A total of 1,466 fan-beam CT scans from 60 patients (40 training, 20 validation) were analyzed. A weighted Trigger Score (TS) was developed, combining volumetric and dosimetric scores in target volumes and key organs-at-risk (parotids, submandibular glands, thyroid, brainstem, spinal cord, optic nerves, chiasm, and temporal lobes). Two trigger modes were defined: 1) an absolute TS ≥65 points, or 2) a TS change ratio ≥1.5 (=TS_y × (y - 2)/Σ TS_2: TS_(y-1), where y = fraction number). In the validation cohort, the model showed high concordance with clinician-simulated triggers, achieving ROC-AUCs of 0.879 (daily) and 0.872 (weekly). The model has been integrated into our clinical ART platform for operational use.
CONCLUSION: We developed and validated a transparent, quantitative trigger model integrating clinical expertise with quantified volumetric/dosimetric changes and structural prioritization to enable individualized ART decision-making for NPC. This model supports automated, real-time ART triggering with adjustable thresholds, adaptable to imaging frequencies, and customizable to institutional practice. However, multicenter or prospective validation is still warranted before widespread clinical adoption.