耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

人工耳蜗骨膜下囊袋移位的客观测量:一项前瞻性研究的长期结果

Objective measurements of subperiosteal pocket migration for cochlear implant: long-term results from a prospective study.

临床研究耳科IF 1.7Q3

文献信息

中文摘要

目的: 通过术中及术后12个月随访的客观测量,评估采用骨膜下紧密囊袋(SPTP)技术后接收-刺激器(RS)的移位情况。
研究设计: 前瞻性临床研究。
地点: Donostia大学医院。
患者: 纳入2019年至2024年间连续接受初次人工耳蜗植入的103例患者。共实施103例人工耳蜗植入手术。所有患者均完成12个月随访方案。
干预: 采用SPTP技术进行人工耳蜗植入以稳定RS,不使用额外固定装置。
主要结局指标: 通过两个标准化线性测量(T距离和P距离)在四个时间点评估RS移位:术中及术后1、6和12个月。主要终点为T距离和P距离随时间的变化。
结果: 共分析386次测量。术中测量与所有术后评估之间,T距离和P距离均观察到显著差异(p < 0.05)。然而,术后1、6和12个月的评估之间未发现显著差异(p > 0.05)。在初始术后变化之后,测量值在整个随访期间保持稳定。
结论: SPTP技术在12个月期间提供了稳定的RS定位。尽管手术与早期术后评估之间出现轻微位置变化,但此后未观察到进行性移位,支持该固定方法的可靠性。

英文摘要

OBJECTIVE: To evaluate receiver-stimulator (RS) migration following the subperiosteal tight pocket (SPTP) technique using objective intraoperative and postoperative measurements over a 12-month follow-up.
STUDY DESIGN: Prospective clinical study.
SETTING: Donostia University Hospital.
PATIENTS: One hundred three consecutive patients undergoing primary cochlear implantation between 2019 and 2024 were included. A total of 103 cochlear implant procedures were performed. All patients completed the 12-month follow-up protocol.
INTERVENTIONS: Cochlear implantation using the SPTP technique for RS stabilization without additional fixation devices.
MAIN OUTCOME MEASURES: RS migration assessed by two standardized linear measurements (T and P distances) obtained at four time points: intraoperatively and at 1, 6, and 12 months postoperatively. The primary endpoint was change in T and P distances over time.
RESULTS: A total of 386 measurements were analyzed. Significant differences were observed in both T and P distances between intraoperative measurements and all postoperative evaluations (p < 0.05). However, no significant differences were found among postoperative assessments at 1, 6, and 12 months (p > 0.05). After the initial postoperative change, measurements remained stable throughout follow-up.
CONCLUSIONS: The SPTP technique provides stable RS positioning over a 12-month period. Although minor positional changes occur between surgery and early postoperative assessment, no progressive migration is observed thereafter, supporting the reliability of this fixation approach.