重离子机架强度控制光栅扫描碳离子放射治疗的临床经验:海德堡离子束治疗中心。

Intensity-controlled Raster Scanning Carbon Ion Radiation Therapy With a Heavy-ion Gantry: Clinical Experience at Heidelberg Ion Beam Therapy Center.

临床研究鼻科IF 7.1Q1

文献信息

中文摘要

目的: 碳离子相较于光子具有生物物理学优势,包括有限射程、更高的相对生物有效性以及更低的氧依赖性。旋转束流投照可实现最大的治疗灵活性。我们报告在海德堡离子束治疗中心使用具备强度控制光栅扫描能力的碳离子机架的临床经验,重点关注治疗毒性。
方法: 对2012年至2026年间使用碳离子机架治疗的1622例患者进行了评估。数据采用描述性统计学分析。毒性分析采用不良事件通用术语标准v5.0进行。
结果: 放疗前中位年龄为59岁(范围18-91岁)。大多数患者为局部晚期肿瘤(21.8%为T4;11.2%为T3),无区域淋巴结转移(45.4%为N0)。最常见的治疗适应证为骶尾部肿瘤(n=331;20.4%),其次为鼻旁窦肿瘤(n=166;10.2%)和脊柱肿瘤(n=121;7.5%)。共有486例患者(30.0%)接受了碳离子再照射,这是所有患者中最常见的碳离子机架治疗适应证。最常见的粒子治疗束流角度数为2(范围1-7)。使用超过2个束流角度在颅底肿瘤(45.8%)和胸部区域肿瘤(40.0%)中尤为常见。在初次治疗中,高级别(III级和IV级)急性和晚期毒性发生率分别为2.4%和4.2%。每例患者急性和晚期I级和II级毒性事件的平均数分别为2.2(95%置信区间2.0-2.4)和2.0(95%置信区间1.7-2.4)。
结论: 使用重离子机架的碳离子放射治疗在特定适应证中产生了良好的毒性发生率。需要进一步的跨学科研究来证明碳离子放射治疗的临床获益。本研究为粒子治疗设施提供了更多证据,并可能作为前瞻性临床试验的基础。

英文摘要

PURPOSE: Carbon ions have biophysical advantages over photons, including a finite range, increased relative biological effectiveness, and lowered oxygen dependence. Maximum treatment flexibility is attainable with rotational beam delivery. We report our clinical experience using the carbon-ion gantry at the Heidelberg Ion Beam Therapy Center with intensity-controlled raster scanning capability, focusing on treatment toxicity.
METHODS AND MATERIALS: A total of 1622 patients treated using the carbon-ion gantry between 2012 and 2026 were evaluated. Data were analyzed using descriptive statistics. Toxicity analysis was conducted using Common Terminology Criteria of Adverse Events v5.0.
RESULTS: The median age preradiation therapy was 59 years (range, 18-91). Most patients had locally advanced tumors (21.8% T4; 11.2% T3) without regional lymph node metastases (45.4% N0). The most common treatment indications were sacrococcygeal tumors (n = 331; 20.4%), followed by tumors of the paranasal sinuses (n = 166; 10.2%) and the spine (n = 121; 7.5%). A total of 486 patients (30.0%) received carbon-ion reirradiation, the most frequent carbon-ion gantry treatment indication viewed across all patients. The most common particle therapy beam-angle number was 2 (range, 1-7). The use of more than 2 beam angles was particularly frequent in tumors of the skull base (45.8%) and the thoracic region (40.0%). High-grade (III and IV) acute and late toxicity rates were 2.4% and 4.2% in primary treatment. Mean numbers of acute and late grade I and II toxicity events per patient were 2.2 (95% confidence interval, 2.0-2.4) and 2.0 (95% confidence interval, 1.7-2.4), respectively.
CONCLUSIONS: Carbon-ion radiation therapy using a heavy-ion gantry resulted in favorable toxicity rates in specific indications. Further interdisciplinary research demonstrating the clinical benefit of carbon-ion radiation therapy is required. This study provides more evidence supporting particle therapy facilities and may serve as a foundation for prospective clinical trials.