耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

药物治疗对阻塞性睡眠呼吸暂停日间嗜睡定量脑电图指标的影响

Effects of pharmacotherapy on quantitative electroencephalogram measures of sleepiness in obstructive sleep apnea.

临床研究鼻科IF 4.5Q1

文献信息

中文摘要

目的: 近期关于去甲肾上腺素能药物和抗毒蕈碱药物用于治疗阻塞性睡眠呼吸暂停(OSA)的研究结果令人鼓舞,但其对主观和客观睡眠质量及日间嗜睡的影响结果不一致。本研究旨在通过在Karolinska嗜睡测试(KDT)期间对清醒脑电图进行定量分析(qEEG),评估去甲肾上腺素能药物瑞波西汀单用及与抗毒蕈碱药物奥昔布宁联用对次日客观嗜睡的影响。
方法: 这是对一项随机试验的二次分析,该试验在16名OSA参与者中比较瑞波西汀单用、瑞波西汀与奥昔布宁联用与安慰剂。所有参与者均在给药或安慰剂及睡眠机会前的晚间,以及次日醒后约1小时接受了KDT。采用混合模型检验药物对qEEG结局的影响。
结果: 在晨间KDT期间,治疗(瑞波西汀 vs 安慰剂 vs 瑞波西汀-奥昔布宁)对慢EEG频率或theta/alpha比值无显著主效应。测试时间(晚间 vs 晨间)有显著主效应,与晚间测试相比,晨间睁眼时delta和theta EEG功率更高,整个KDT期间delta功率也更高(均p < 0.001)。电极位置(F3、C3、O1)对清醒delta和theta EEG有显著主效应,两种频率在额区(F3)均高于枕区(O1)(均p < 0.001)。无交互效应,且qEEG结局与晨间主观嗜睡之间无相关性。
结论: 瑞波西汀单用或联用奥昔布宁并未增加以清醒delta和theta EEG功率测量的次日晨间嗜睡神经生理标志物。这些发现支持这些药物在OSA患者次日嗜睡方面具有潜在安全性特征。

英文摘要

OBJECTIVE: Recent studies of noradrenergic and antimuscarinic agents to treat obstructive sleep apnoea (OSA) have been promising, but their impact on subjective and objective sleep quality and daytime sleepiness have shown inconsistent results. This study aimed to assess the effects of the noradrenergic agent reboxetine alone and in combination with the antimuscarinic oxybutynin on next-day objective sleepiness through quantitative analysis of wake electroencephalography (qEEG) during a Karolinska Drowsiness Test (KDT).
METHODS: This was a secondary analysis from a randomised trial of reboxetine alone and in combination with oxybutynin versus placebo in 16 participants with OSA. All participates have undergone a KDT in the evening prior to drug or placebo administration and sleep opportunity, and ∼1hr post-waking next morning. Mixed models were used to examine drug effects on qEEG outcomes.
RESULTS: There was no significant main effect of treatment (Reboxetine vs placebo vs Reboxetine-Oxybutynin) on slow EEG frequencies or theta/alpha ratio during the morning KDT. There was a significant main effect of testing time (evening vs morning) with higher morning delta and theta EEG power during eyes open and the delta power during entire KDT (all p < 0.001) compared to the evening test. There was a significant main effect of electrode position (F3, C3, O1), on wake delta and theta EEG with both frequencies higher in frontal (F3) vs occipital regions (O1) (all p < 0.001). There were no interaction effects and no correlations between qEEG outcomes and morning subjective sleepiness.
CONCLUSION: Reboxetine with and without oxybutynin did not increase neurophysiological markers of next-day morning sleepiness as measured by wake delta and theta EEG power. These findings support the potential safety profile of these agents in respect to next-day sleepiness in people with OSA.