耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

丙泊酚麻醉下幼儿脑电图衍生95%谱边缘频率目标值

Electroencephalography-derived spectral edge frequency 95 targets in toddlers under propofol anaesthesia✰.

临床研究咽喉科IF 10.8Q1

文献信息

中文摘要

背景: 专有处理脑电图指标在幼儿中准确性较低。我们评估了95%谱边缘频率(SEF95),一种非专有脑电图指标,代表总脑电功率95%所在的频率以下值,以建立丙泊酚麻醉期间不同麻醉深度的目标阈值。次要目标是评估SEF95与丙泊酚血浆浓度的关系,并评估喉镜检查期间的气道反应性。
方法: 在这项针对13至24个月幼儿的前瞻性研究中,使用Dixon上下法和中心等渗回归确定对三种临床刺激无反应概率为50%(ED50)和90%(ED90)的SEF95目标值:安抚奶嘴放置(评估意识)、电神经刺激(伤害感受)和喉镜检查(插管准备)。使用线性混合效应回归分析丙泊酚血浆浓度与SEF95之间的关联。
结果: 在51名幼儿中,安抚奶嘴放置的SEF95 ED50和ED90目标值(Hz)分别为21.8(90% CI 20.8-23.4)和20.3(19.1-20.7)Hz,电刺激为12.0(10.8-18.3)和10.4(8.7-11.3)Hz,喉镜检查为10.3(4.6-11.8)和4.4(1.5-5.4)Hz。SEF95每增加1 Hz,丙泊酚血浆浓度降低0.21 μg ml-1(r=0.46,P<0.001),如方程所述:丙泊酚血浆浓度(μg ml-1)=5.80-0.21×SEF95(Hz)。
结论: 本研究定义了13至24个月幼儿意识丧失、对伤害性刺激反应和插管准备的脑电图SEF95目标值。结合现有婴儿数据,这些年龄特异性SEF95目标值可在2岁以下患者的脑电图引导丙泊酚麻醉中优化丙泊酚滴定和给药准确性。
临床试验注册: NCT05701748。注册日期2023年1月17日;PI:Ian Yuan。

英文摘要

BACKGROUND: Proprietary processed EEG indices are less accurate in young children. We evaluated spectral edge frequency 95 (SEF95), a nonproprietary EEG index representing the frequency below which 95% of total EEG power resides, to establish target thresholds for varying anaesthetic depths during propofol anaesthesia in toddlers. Secondary objectives were to assess the relationship between SEF95 and plasma propofol concentration, and to evaluate airway reactivity during laryngoscopy.
METHODS: In this prospective study of toddlers aged 13 to 24 months, Dixon's up-and-down method and centred isotonic regression were used to determine the SEF95 targets for 50% (ED50) and 90% (ED90) probability of nonresponse to three clinical stimuli: pacifier placement (assessing consciousness), electrical nerve stimulation (nociception), and laryngoscopy (intubation readiness). Linear mixed-effects regression was used to analyse the association between plasma propofol concentration and SEF95.
RESULTS: Among 51 toddlers, SEF95 ED50 and ED90 targets (Hz) were 21.8 (90% CI 20.8-23.4) and 20.3 (19.1-20.7) Hz for pacifier placement, 12.0 (10.8-18.3) and 10.4 (8.7-11.3) Hz for electrical stimulation, and 10.3 (4.6-11.8) and 4.4 (1.5-5.4) Hz for laryngoscopy. Each 1 Hz increase in SEF95 corresponded to a 0.21 μg ml-1 decrease in plasma propofol (r=0.46, P<0.001), as described by the equation: plasma propofol concentration (μg ml-1)=5.80-0.21×SEF95 (Hz).
CONCLUSIONS: This study defined EEG SEF95 targets for loss of consciousness, response to noxious stimuli, and intubation readiness in toddlers aged 13 to 24 months. When combined with existing infant data, these age-specific SEF95 targets can optimise propofol titration and dosing accuracy during EEG-guided propofol anaesthesia in patients aged <2 yr.
CLINICAL TRIAL REGISTRATION: NCT05701748. Registered 17 January 2023; PI: Ian Yuan.