光子计数计算机断层扫描提高了镫骨手术失败评估中的观察者间一致性。
Photon-counting computed tomography improves interobserver agreement in the evaluation of failed stapes surgery.
文献信息
| PMID | 43037671 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Simon Beatty |
| 作者单位 | Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic Arizona, Phoenix, USA. |
| 期刊 | Neuroradiology |
| SCI 分区 | Q2 |
| IF | 2.8 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 耳科 |
中文摘要
目的: 失败的镫骨手术提出了一个诊断挑战,需要高分辨率成像来指导翻修。光子计数CT(PCCT)与传统能量积分探测器CT(EID-CT)相比,提供了更高的空间分辨率和更低的噪声。本研究比较了PCCT和EID-CT在识别原发性镫骨手术失败病因方面的作用,重点关注诊断准确性、观察者间一致性和判读者信心。
方法: 在这项回顾性研究中,纳入了38例原发性镫骨手术失败且成功接受翻修手术并有翻修前CT的患者;18例接受了PCCT,20例接受了EID-CT。三名专家评审员独立确定手术失败的原因,以翻修术中的术中发现作为参考标准。比较了两种模态之间的诊断准确性、观察者间一致性(Fleiss kappa)和判读者信心。
结果: PCCT的总体观察者间一致性(κ = 0.75;95% CI,0.60-0.90)高于EID-CT(κ = 0.44;95% CI,0.30-0.59),总体一致性和听骨链不连续的置信区间不重叠。共识诊断准确性在两种模态之间无显著差异(PCCT 88.9% vs. EID-CT 85.0%;p = 1.00),判读者信心也无显著差异(4.33 vs. 4.17;p = 0.29)。
结论: 在这个小队列中,PCCT显示出比EID-CT更高的观察者间一致性,而在诊断准确性或判读者信心方面无统计学显著差异,提示对失败镫骨手术的评估更具可重复性。
英文摘要
PURPOSE: Failed stapes surgery presents a diagnostic challenge requiring high-resolution imaging to guide revision. Photon-counting CT (PCCT) offers improved spatial resolution and reduced noise compared with conventional energy-integrating detector CT (EID-CT). This study compared PCCT and EID-CT for identifying etiologies of failed primary stapes surgery, with emphasis on diagnostic accuracy, interobserver agreement, and interpreter confidence.
METHODS: In this retrospective study, 38 patients with failed primary stapes surgery who underwent successful revision surgery and pre-revision CT were included; 18 underwent PCCT and 20 underwent EID-CT. Three expert reviewers independently determined the cause of surgical failure using intraoperative findings at revision as the reference standard. Diagnostic accuracy, interobserver agreement (Fleiss kappa), and reader confidence were compared between modalities.
RESULTS: Overall interobserver agreement was higher with PCCT (κ = 0.75; 95% CI, 0.60-0.90) than EID-CT (κ = 0.44; 95% CI, 0.30-0.59), with non-overlapping confidence intervals for overall agreement and ossicular discontinuity. Consensus diagnostic accuracy did not significantly differ between modalities (88.9% PCCT vs. 85.0% EID-CT; p = 1.00), nor did interpreter confidence (4.33 vs. 4.17; p = 0.29).
CONCLUSION: In this small cohort, PCCT demonstrated higher interobserver agreement than EID-CT without statistically significant differences in diagnostic accuracy or reader confidence, suggesting more reproducible assessment of failed stapes surgery.