噪声性前庭电刺激对青少年特发性脊柱侧凸步态对称性的任务特异性效应
Task-specific effects of noisy galvanic vestibular stimulation on gait symmetry in adolescent idiopathic scoliosis.
文献信息
| PMID | 43036715 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Yan Li |
| 作者单位 | Rehabilitation Medicine Center, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China. |
| 期刊 | PeerJ |
| SCI 分区 | Q2 |
| IF | 2.9 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 耳科 |
中文摘要
背景: 前庭功能障碍已被认为是青少年特发性脊柱侧凸(AIS)姿势不稳和步态不对称的潜在促成因素。噪声性前庭电刺激(nGVS)通过随机共振优化前庭信号处理来增强步态表现。然而,nGVS如何调节AIS患者的步态对称性,以及其疗效是否取决于运动任务或脊柱畸形严重程度,仍有待阐明。本研究旨在探讨nGVS对AIS患者在平地行走和单步上下楼梯时内外侧步态对称性的影响。
方法: 这项单组交叉研究招募了30例AIS患者,在nGVS、假刺激和无刺激条件下进行平地行走、上楼梯和下楼梯。主要因变量包括运动学域(躯干侧向位移(T)、躯干侧倾(α)、骨盆侧向位移(P)、骨盆倾斜(β)和髋内收(θ))和动力学域(第一(ML1)和第二(ML2)内外侧地面反作用力峰值)的内外侧步态对称性,通过对称指数(SI)和归一化互相关系数(Xcorr)量化。事后比较优先考虑(nGVS vs. 假刺激)对比,以分离真正的nGVS疗效。还检查了假刺激对照的净疗效(Δ)与Cobb角之间的相关性。
结果: 与假刺激相比,nGVS在单步上下楼梯期间显著增加Xcorr_α(下楼梯:p = 0.017;上楼梯:p = 0.033)、Xcorr_β(下楼梯:p = 0.006)、Xcorr_θ(上楼梯:p = 0.008)和Xcorr_ML(下楼梯:p < 0.001),同时降低SI_ML1(下楼梯:p = 0.015;上楼梯:p = 0.022)。相关性分析显示,较大的Cobb角与Δ Xcorr_ML(下楼梯:ρ = 0.583,p = 0.001;上楼梯:r = 0.575,p = 0.001)、Δ Xcorr_α(下楼梯:r = 0.539,p = 0.002;上楼梯:ρ = 0.427,p = 0.019)、Δ Xcorr_β(下楼梯:ρ = 0.394,p = 0.031)、Δ Xcorr_θ(上楼梯:r = 0.398,p = 0.030)和Δ SI_ML1(下楼梯:ρ = -0.444,p = 0.014)显著相关。然而,这种状态依赖性关系在Δ SI_α(r = -0.394,p = 0.137)和Δ SI_β(r = -0.423,p = 0.108)上未达到统计学显著性。
结论: 这些发现表明,nGVS通过在更高的生物力学需求下改善多节段控制,改善了AIS患者的内外侧步态对称性,提示存在任务特异性模式。此外,nGVS诱导的内外侧步态对称性改善具有状态依赖性,其中在轻至中度范围(10°-30°)内表现出较大Cobb角的患者获得了更大的生物力学收益。
英文摘要
BACKGROUND: Vestibular dysfunction has been identified as a potential contributor to postural instability and gait asymmetry in adolescent idiopathic scoliosis (AIS). Noisy galvanic vestibular stimulation (nGVS) enhances gait performance by optimizing vestibular signal processing via stochastic resonance. However, how nGVS modulates gait symmetry in AIS and whether its efficacy depends on locomotor tasks or spinal deformity severity remain to be elucidated. This study aimed to investigate the effects of nGVS on medial-lateral gait symmetry in patients with AIS during level walking and single-step stair negotiation.
METHODS: This single-group crossover study recruited 30 patients with AIS to perform level walking, stair ascent, and stair descent under nGVS, sham-stimulation, and no-stimulation conditions. Primary dependent measures included medial-lateral gait symmetry across kinematic (lateral trunk displacement (T), lateral trunk lean (α), lateral pelvic displacement (P), pelvic obliquity (β), and hip adduction (θ)) and kinetic domains (first (ML1) and second (ML2) medial-lateral ground reaction force peaks), quantified by the symmetry index (SI) and normalized cross-correlation coefficient (Xcorr). Post-hoc comparisons prioritized the (nGVS vs. sham) contrast to isolate true nGVS efficacy. Correlations between the sham-controlled net efficacy (Δ) and Cobb angle were also examined.
RESULTS: Compared to sham stimulation, nGVS significantly increased Xcorr_α (descent: p = 0.017; ascent: p = 0.033), Xcorr_β (descent: p = 0.006), Xcorr_θ (ascent: p = 0.008), and Xcorr_ML (descent: p < 0.001), while decreasing SI_ML1 (descent: p = 0.015; ascent: p = 0.022) during single-step stair negotiation. Correlation analyses revealed that greater Cobb angle was significantly correlated with Δ Xcorr_ML (descent: ρ = 0.583, p = 0.001; ascent: r = 0.575, p = 0.001), Δ Xcorr_α (descent: r = 0.539, p = 0.002; ascent: ρ = 0.427, p = 0.019), Δ Xcorr_β (descent: ρ = 0.394, p = 0.031), Δ Xcorr_θ (ascent: r = 0.398, p = 0.030), and Δ SI_ML1 (descent: ρ = - 0.444, p = 0.014). However, this state-dependent relationship did not reach statistical significance across Δ SI_α (r = - 0.394, p = 0.137) and Δ SI_β (r = - 0.423, p = 0.108).
CONCLUSIONS: These findings demonstrated that nGVS ameliorated medial-lateral gait symmetry in AIS by refining multi-segmental control under heightened biomechanical demands, indicating a task-specific pattern. Furthermore, nGVS-induced enhancements in medial-lateral gait symmetry were state-dependent, wherein patients exhibiting larger Cobb angles within the mild-to-moderate range (10°-30°) derived greater biomechanical gains.