自体与尸体肋软骨移植鼻整形术后患者报告的功能与美容结局比较
Patient-Reported Functional and Cosmetic Outcomes after Rhinoplasty with Autologous Versus Cadaveric Rib Cartilage Grafts.
文献信息
| PMID | 43035971 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Daniel K Du |
| 作者单位 | Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA. |
| 期刊 | Facial plastic surgery & aesthetic medicine |
| SCI 分区 | Q2 |
| IF | 2 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 鼻科 |
中文摘要
背景: 比较使用不同肋软骨来源进行鼻整形术后患者报告的呼吸和外观结局的证据有限。
目的: 通过标准化美容与健康鼻结局调查及翻修率,比较接受自体与尸体肋软骨移植鼻整形的患者结局。
方法: 本回顾性队列纳入2018年至2025年间治疗的129名成人(33例自体;96例尸体)。主要结局为纵向患者报告的阻塞和美容评分,采用校正混合效应模型分析。次要结局包括翻修率和并发症。
结果: 肋软骨移植物用作撑开移植物123例(95.3%)、鼻中隔移植物113例(87.6%)、外侧移植物47例(36.4%)和覆盖移植物43例(33.3%)。自体移植受者在随访期间平均阻塞评分较低(差值 = -14.02;95%置信区间[CI]:-24.19至-3.85),而美容评分相似(差值 = -7.05;95% CI:-16.33至2.22)。两组在所有术后时间点的阻塞和美容改善均超过最小临床重要差异。翻修发生在15.2%的自体移植受者 versus 24.0%的尸体移植受者(差值 = -8.8%;95% CI:-21.5%至8.6%)。
结论: 两种移植物来源均在呼吸和外观方面产生有临床意义的改善,自体移植受者在随访期间平均阻塞评分较低,尽管翻修率的差异值得未来研究。
英文摘要
BACKGROUND: Evidence comparing patient-reported breathing and appearance outcomes after rhinoplasty using different rib cartilage sources is limited.
OBJECTIVE: To compare outcomes among patients undergoing rhinoplasty grafting with autologous versus cadaveric rib grafts, as measured by the Standardized Cosmesis and Health Nasal Outcomes Survey and revision rates.
METHODS: This retrospective cohort included 129 adults (33 autologous; 96 cadaveric) treated between 2018 and 2025. Primary outcomes were longitudinal patient-reported obstruction and cosmetic scores analyzed using adjusted mixed-effects models. Secondary outcomes included revision rates and complications.
RESULTS: Rib cartilage grafts were used as spreader grafts in 123 patients (95.3%), septal grafts in 113 (87.6%), lateral grafts in 47 (36.4%), and onlay grafts in 43 (33.3%). Autologous recipients had lower mean obstruction scores across follow-up (difference = -14.02; 95% confidence interval [CI]: -24.19 to -3.85), while cosmetic scores were similar (difference = -7.05; 95% CI: -16.33 to 2.22). Both groups exceeded the minimal clinically important differences for obstruction and cosmetic improvements at all postoperative intervals. Revisions occurred in 15.2% of autologous versus 24.0% of cadaveric recipients (difference = -8.8%; 95% CI: -21.5% to 8.6%).
CONCLUSIONS: Both graft sources yielded clinically meaningful improvements in breathing and appearance, with autologous recipients exhibiting lower average obstruction scores across follow-up, although the difference in revision rates warrants future investigation.