耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

多参考评估深度学习肿瘤分割在多序列鼻咽癌MRI中的表现

Multi-Reference Evaluation of Deep Learning Tumour Segmentation in Multi-Sequence Nasopharyngeal Carcinoma MRI.

AI/ML鼻咽癌IF 3.6Q1

文献信息

中文摘要

背景/目的: 鼻咽癌的深度学习分割通常以相对于单一参考掩膜的单一Dice相似系数(DSC)来报告,尽管多序列MRI常在各序列上分别勾画。我们旨在量化参考选择对报告性能的影响程度,并将其与放射科医师之间的不一致进行比较。方法:我们分析了一个公共数据集,包含277例患者记录,分别勾画了T1加权、T2加权和对比增强T1加权MRI,其中30例由两位放射科医师标注。肿瘤体积在未配准的情况下进行比较。空间一致性在刚性配准后测量,并单独估计掩膜在采集网格之间转移的损失。nnU-Net模型在102例留出患者记录中针对每个参考(包括第二位放射科医师的参考)进行评分。结果:未配准时,序列对肿瘤体积的影响为10.9%,而读者效应为5.7%(比值1.9,95% CI 1.40至2.49)。刚性配准后,各序列参考之间的中位DSC一致性为0.783,而放射科医师之间为0.898;在双标注患者记录中,当网格转移匹配时,配对差距仅从0.129缩小至0.083(95% CI 0.063至0.111)。一组固定预测仅因参考不同而分别得分为0.726、0.685和0.673(每患者参考中位差异0.075),切换参考序列使得分变化为切换放射科医师的2.7至3.6倍。结论:跨序列差异的一部分是各序列所显示内容的差异,而非标注错误,因此多序列数据上的单参考DSC取决于一个很少被说明的选择。性能应针对每个可用参考报告,并结合测得的读者间一致性来解读。

英文摘要

Background/Objectives: Deep learning segmentation of nasopharyngeal carcinoma is usually reported as one Dice similarity coefficient (DSC) against one reference mask, although multi-sequence MRI is often delineated separately on each sequence. We aimed to quantify how far the choice of reference changes reported performance, and to compare this with the disagreement between radiologists. Methods: We analysed a public dataset of 277 patient records with separately delineated T1-weighted, T2-weighted and contrast-enhanced T1-weighted MRI, 30 of whom were annotated by two radiologists. Tumour volumes were compared without registration. Spatial agreement was measured after rigid registration, with the loss from transferring masks between acquisition grids estimated separately. nnU-Net models were scored against every reference, including the second radiologist's, in 102 held-out patient records. Results: Without registration, the sequence effect on tumour volume was 10.9%, against a reader effect of 5.7% (ratio 1.9, 95% CI 1.40 to 2.49). After rigid registration, per-sequence references agreed at a median DSC of 0.783, against 0.898 between radiologists; in the double-annotated patient records, the paired gap narrowed only from 0.129 to 0.083 (95% CI 0.063 to 0.111) when grid transfer was matched. One fixed set of predictions scored 0.726, 0.685 and 0.673, depending only on the reference (median per-patient reference spread 0.075), and switching the reference sequence moved scores 2.7 to 3.6 times as much as switching the radiologist. Conclusions: Part of the cross-sequence difference is a difference in what each sequence makes visible rather than annotation error, so a single-reference DSC on multi-sequence data depends on a rarely stated choice. Performance should be reported against every available reference and read against measured inter-reader agreement.