耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

使用电子鼻装置通过呼出气体检测巴雷特食管:一项多中心验证研究

Detection of Barrett's esophagus through exhaled breath using an electronic nose device: a multicenter validation study.

临床研究鼻科IF 2.7Q3

文献信息

中文摘要

背景: 过去30年来,西方世界食管腺癌的发病率急剧上升,尤其由胃食管反流病(GERD)和巴雷特食管(BE)驱动。我们旨在评估挥发性有机化合物(VOC)呼气检测能否预测BE,并在包括BE参与者、GERD参与者和对照者的独立队列中验证其性能。方法:2017年8月至2022年7月期间转诊接受胃镜检查的年龄≥18岁参与者符合纳入条件。使用四种机器学习算法(MLA)评估VOC呼气检测的诊断准确性:(1)随机森林,(2)极端随机树,(3)极端梯度提升(XGBoost),以及(4)卷积神经网络。患者对呼气检测的耐受性和可接受性是次要结局指标。结果:共纳入1079名参与者,训练队列602名(55.8%),验证队列477名(44.2%)。在训练队列中,XGBoost在区分BE与GERD及对照者方面表现最佳的MLA(受试者工作特征曲线下面积[AUROC] 0.892 [95% CI,0.862-0.921])。然而,在验证队列中,XGBoost的性能显著下降(AUROC 0.530 [95% CI,0.472-0.589])。耐受性评分中位数为2.00(0为“无不适”,10为“可想象的最严重不适”),可接受性评分中位数为8.00(0为“最差体验”,10为“最佳体验”)。结论:当前形式的VOC呼气检测不能为BE筛查提供额外的诊断价值;然而,基于患者的高度可接受性,进一步研究eNose技术似乎是合理的。

英文摘要

Esophageal adenocarcinoma incidence has risen dramatically in the Western world over the past 30 years, particularly driven by gastroesophageal reflux disease (GERD) and Barrett's esophagus (BE). We aimed to assess whether Volatile Organic Compound (VOC) breath testing can predict BE and to validate its performance in independent cohorts including participants with BE, participants with GERD, and controls. Participants aged ≥18 years referred for gastroscopy between August 2017 and July 2022, were eligible for inclusion. The diagnostic accuracy of VOC breath testing was assessed using four machine learning algorithms (MLAs): (1) random forest, (2) extremely randomized trees, (3) eXtreme Gradient Boosting (XGBoost), and (4) convolutional neural network. Patient tolerability and patient acceptability of breath testing were secondary outcome measures. A total of 1079 participants were included, 602 (55.8%) in the training cohort and 477 (44.2%) in the validation cohort. In the training cohort, XGBoost was the best performing MLA in differentiating BE from GERD and controls (area under the receiver operating characteristic [AUROC] 0.892 [95% CI, 0.862-0.921]). However, in the validation cohort, the performance of XGBoost markedly declined (AUROC 0.530 [95% CI, 0.472-0.589]). Median tolerability score was 2.00 with 0 'no discomfort' and 10 'worst discomfort imaginable', and median acceptability score was 8.00 with 0 'worst experience' and 10 'best experience'. VOC breath testing in its current form does not provide additional diagnostic value for BE screening; however, based on the high degree of patient acceptability, further research on eNose technology seems justified.