不同中文连续言语材料在儿童声带小结声学嗓音评估中的一致性与一致性分析
Consistency and Agreement Across Different Chinese Connected Speech Materials in Acoustic Voice Assessment of Pediatric Vocal Fold Nodules.
文献信息
| PMID | 43020747 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Xiaoxu Zhang |
| 作者单位 | Department of Otolaryngology, Children's Hospital of Nanjing Medical University, Nanjing, China. |
| 期刊 | Journal of voice : official journal of the Voice Foundation |
| SCI 分区 | Q1 |
| IF | 2.4 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 咽喉科 |
中文摘要
背景: 儿童声带小结(PVFNs)是儿童发声困难的常见原因。基于连续言语得出的声学结果可能受到所选言语材料的影响,但不同中文连续言语材料在PVFNs患儿中的影响仍不清楚。
目的: 比较三种中文连续言语材料的声学测量结果,并评估其一致性和一致性。
方法: 纳入67例确诊为PVFNs的儿童。参与者完成《北风和太阳》《和爸爸钓鱼》和《生日礼物》。声学测量包括声学嗓音质量指数(AVQI)、声学气息声指数(ABI)、平滑倒谱峰突出度(CPPS)、Jitter、Shimmer、谐噪比(HNR)、声门噪声激发比(GNE)、频谱斜率、频谱倾斜和H1-H2。采用Friedman检验及Bonferroni校正的配对Wilcoxon符号秩检验进行受试者内比较。采用组内相关系数(ICC)和Bland-Altman分析评估一致性和两两一致性。
结果: Friedman检验发现不同材料间在AVQI(χ²(2) = 27.46,P = 1.09×10⁻⁶)、ABI(χ²(2) = 11.52,P = 0.003)、CPPS(χ²(2) = 34.97,P = 2.55×10⁻⁸)、Shimmer(χ²(2) = 6.48,P = 0.039)、HNR(χ²(2) = 11.76,P = 0.003)、GNE(χ²(2) = 11.47,P = 0.003)和频谱斜率(χ²(2) = 21.43,P = 2.22×10⁻⁵)存在差异,但Jitter、频谱倾斜或H1-H2无差异。AVQI、ABI、CPPS、Jitter、Shimmer、HNR和GNE的ICC估计值较高,而频谱斜率、频谱倾斜和H1-H2的ICC较低。Bland-Altman结果显示参数依赖性偏倚和一致性界限。
结论: 一致性因声学参数而异。几种常用声学测量在三种言语材料间显示出较高的相对一致性,而频谱测量的一致性较低。由于某些参数在不同材料间存在系统性差异,结果支持一致选择言语材料,而非无限制互换。
英文摘要
BACKGROUND: Pediatric vocal fold nodules (PVFNs) are a common cause of childhood dysphonia. Acoustic outcomes derived from connected speech may be affected by the speech material selected, but the influence of different Chinese connected-speech materials in children with PVFNs remains unclear.
OBJECTIVE: To compare acoustic measures across three Chinese connected-speech materials and evaluate their consistency and agreement.
METHODS: Sixty-seven children diagnosed with PVFNs were enrolled. Participants completed The North Wind and the Sun, Fishing with My Father, and Birthday Gift. Acoustic measures included the Acoustic Voice Quality Index (AVQI), Acoustic Breathiness Index (ABI), smoothed cepstral peak prominence (CPPS), Jitter, Shimmer, harmonics-to-noise ratio (HNR), glottal-to-noise excitation ratio (GNE), spectral slope, spectral tilt, and H1-H2. Friedman tests with Bonferroni-adjusted paired Wilcoxon signed-rank tests were used for within-participant comparisons. Intraclass correlation coefficients (ICCs) and Bland-Altman analyses assessed consistency and pairwise agreement.
RESULTS: Friedman tests identified differences across materials for AVQI (χ²(2) = 27.46, P = 1.09×10⁻⁶), ABI (χ²(2) = 11.52, P = 0.003), CPPS (χ²(2) = 34.97, P = 2.55×10⁻⁸), Shimmer (χ²(2) = 6.48, P = 0.039), HNR (χ²(2) = 11.76, P = 0.003), GNE (χ²(2) = 11.47, P = 0.003), and spectral slope (χ²(2) = 21.43, P = 2.22×10⁻⁵), but not for Jitter, spectral tilt, or H1-H2. ICC estimates were high for AVQI, ABI, CPPS, Jitter, Shimmer, HNR, and GNE, whereas spectral slope, spectral tilt, and H1-H2 had lower ICCs. Bland-Altman results showed parameter-dependent biases and limits of agreement.
CONCLUSION: Consistency varied by acoustic parameter. Several commonly used acoustic measures showed high relative consistency across the three speech materials, whereas spectral measures were less consistent. Because some parameters differed systematically across materials, the results support consistent selection of speech material rather than unrestricted interchangeability.