耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

人工耳蜗植入手术中同步术中eCAP和eABR记录揭示互补的神经反应特征

Simultaneous Intraoperative eCAP and eABR Recordings During Cochlear Implant Surgery Reveal Complementary Neural Response Characteristics.

临床研究耳科IF 6.7Q1

文献信息

中文摘要

目的: 电诱发复合动作电位(eCAP)和电诱发听性脑干反应(eABR)为人工耳蜗使用者提供外周和脑干水平听觉功能的互补信息。同步记录可能实现高效的术中评估,但其可行性和模态间一致性仍缺乏充分表征。
方法: 对20名成年人工耳蜗植入者进行术中研究,采用统一刺激范式,使用双相脉冲(80 pps,500次平均)和扩展刺激范围。同步记录eCAP和eABR(波V,ej5)反应。使用S形拟合对振幅增长函数(AGF)建模,以提取阈值(THR)、斜率、饱和水平(SLS)和饱和振幅(AS)。分析模态间相关性和极性效应。
结果: 在联合eCAP/eABR方案中,75%的病例可检测到eCAP反应,而标准自动eCAP方案为85%;65%的病例可检测到eABR,60%的病例实现同步记录。eCAP与eABR阈值之间发现强相关性(R = 0.90,p < 0.001),而斜率和饱和参数显示较弱或无相关性。eCAP阈值和SLS系统性高于相应的eABR测量值。脉冲极性对AGF衍生参数无影响,但阴极优先刺激导致基线噪声降低和eABR潜伏期轻度延长。
结论: 同步术中eCAP和eABR记录可行,并获得高度相关的阈值估计,支持二者对刺激水平的共同依赖。动态和时间参数的差异表明对听觉通路功能的互补敏感性,支持联合术中评估的价值。

英文摘要

OBJECTIVE: Electrically evoked compound action potentials (eCAP) and electrically evoked auditory brainstem responses (eABR) provide complementary information on peripheral and brainstem-level auditory function in cochlear implant users. Simultaneous recordings may enable efficient intraoperative assessment, but feasibility and intermodal agreement remain insufficiently characterized.
METHODS: Twenty adult cochlear implant recipients were investigated intraoperatively using a unified stimulation paradigm with biphasic pulses (80 pps, 500 averages) and an extended stimulation range. eCAP and eABR (Wave V, ej5) responses were recorded simultaneously. Amplitude growth functions (AGF) were modeled using sigmoidal fits to extract threshold (THR), slope, saturation level (SLS), and saturation amplitude (AS). Intermodal correlations and polarity effects were analyzed.
RESULTS: eCAP responses were detectable in 75% of cases with the combined eCAP/eABR protocol, compared with 85% using the standard automated eCAP protocol, and eABRs in 65%, with simultaneous recordings in 60%. A strong correlation was found between eCAP and eABR thresholds (R = 0.90, p < 0.001), whereas slope and saturation parameters showed weaker or no correlations. eCAP thresholds and SLS were systematically higher than corresponding eABR measures. Pulse polarity had no effect on AGF-derived parameters, but cathodic-first stimulation resulted in reduced baseline noise and slightly prolonged eABR latencies.
CONCLUSION: Simultaneous intraoperative eCAP and eABR recordings are feasible and yield highly correlated threshold estimates, supporting a shared dependence on stimulus level. Differences in dynamic and temporal parameters indicate complementary sensitivity to auditory pathway function, supporting the value of combined intraoperative assessment.