耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

下颌前移装置与持续气道正压通气对阻塞性睡眠呼吸暂停患者心脏重构的影响:一项随机CMR子研究

Effects of mandibular advancement device versus continuous positive airway pressure on cardiac remodeling in obstructive sleep apnea: a randomized CMR substudy.

临床研究咽喉科IF 4.8Q1

文献信息

中文摘要

背景: 阻塞性睡眠呼吸暂停(OSA)与不良心脏重构相关,包括弥漫性心肌纤维化。持续气道正压通气(CPAP)是OSA的标准治疗,而下颌前移装置(MAD)可能是一种替代方案。然而,两者对心肌结构的比较效应仍未完全明确。目的:比较MAD与CPAP对OSA患者经心血管磁共振(CMR)评估的心脏重构的影响。方法:这项随机CRESCENT试验的预设CMR子研究纳入了同意参加基线和12个月CMR检查的患者(年龄59±8岁,89%为男性,合并高血压、心血管风险升高及中重度OSA)。平均体重指数为28.6±4.6 kg/m2。参与者在基线和接受MAD(n=36)或CPAP(n=49)治疗12个月后接受增强CMR。CMR衍生指标包括左心室(LV)质量、心脏容积和功能;以及作为弥漫性心肌纤维化标志物的细胞外容积(ECV)分数。结果:基线时,平均24小时收缩压为126±11mmHg,ECV分数为25.0±2.0%,27%的参与者符合LV肥厚的CMR标准。12个月后,接受MAD治疗的患者(24.9±2.3%至24.0±2.2%;P=0.047)和CPAP治疗的患者(25.1±1.9%至24.4±1.6%;P=0.004)均观察到ECV分数适度但显著的降低。MAD与CPAP之间ECV分数降低无显著差异(P=0.576)。在LV质量、心脏容积和功能变化方面未观察到显著的组间差异。结论:MAD和CPAP均与12个月内ECV分数的适度降低相关,未检测到组间差异。未观察到LV质量或心脏功能的伴随改善,可能反映基线时心肌表型以保留为主。(阻塞性睡眠呼吸暂停、血压控制与不良心肌重构研究计划-非劣效性试验[CRESCENT];NCT04119999)。补充信息:在线版本包含补充材料,可访问https://doi.org/10.1038/s41598-026-67940-w。

英文摘要

UNLABELLED: Obstructive sleep apnea (OSA) is associated with adverse cardiac remodeling, including diffuse myocardial fibrosis. Continuous positive airway pressure (CPAP) is the standard treatment for OSA, while mandibular advancement devices (MAD) may represent an alternative. However, their comparative effects on myocardial structure remain incompletely defined. To compare the effects of MAD and CPAP on cardiac remodeling assessed by cardiovascular magnetic resonance (CMR) in patients with OSA. This prespecified CMR substudy of the randomized CRESCENT trial included patients who agreed to participate in both baseline and 12-month CMR examinations (aged 59±8 years, 89% male, with hypertension, elevated cardiovascular risk and moderate-to-severe OSA). The mean body mass index was 28.6±4.6 kg/m2. Participants underwent contrast-enhanced CMR at baseline and after 12 months of treatment with either MAD (n = 36) or CPAP (n = 49). CMR-derived measures included left ventricular (LV) mass, cardiac volumes and function; and extracellular volume (ECV) fraction as a marker of diffuse myocardial fibrosis. At baseline, mean 24-hour systolic blood pressure was 126 ± 11mmHg, ECV fraction was 25.0 ± 2.0% and 27% of participants met CMR criteria of LV hypertrophy. After 12 months, a modest but significant reduction in ECV fraction was observed in patients treated with MAD (24.9 ± 2.3% to 24.0 ± 2.2%; P = 0.047) and CPAP (25.1 ± 1.9% to 24.4 ± 1.6%; P = 0.004). There was no significant difference in ECV fraction reduction between MAD and CPAP (P = 0.576). No significant between-group differences were observed for changes in LV mass, cardiac volumes and function. Both MAD and CPAP were associated with modest reductions in ECV fraction over 12 months, with no detectable between-group difference. No accompanying improvements in LV mass or cardiac function were observed, likely reflecting the predominantly preserved myocardial phenotype at baseline. (Cardiosleep Research Program on Obstructive Sleep Apnea, Blood Pressure Control and Maladaptive Myocardial Remodeling-Non-inferiority Trial [CRESCENT]; NCT04119999).
SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at https://doi.org/10.1038/s41598-026-67940-w.