真实世界手持智能手机视频用于急性眩晕中眼震检测:一项可行性研究
Real-world handheld smartphone videos for nystagmus detection in acute vertigo: a feasibility study.
文献信息
| PMID | 43018752 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Elvira Cortese |
| 作者单位 | Department of Clinical and Movement Neurosciences, SENSE Research Unit, Institute of Neurology, University College London, London, UK. |
| 期刊 | Journal of neurology |
| SCI 分区 | Q1 |
| IF | 5.3 |
| 研究类型 | AI/ML · 临床 |
| 所属专科 | 耳科 |
中文摘要
背景: 准确识别眼震是急性眩晕评估的基础,但在急诊科环境中仍然具有挑战性。尽管基于智能手机的方法已被提出作为可扩展的解决方案,但其在真实世界采集条件下的可行性仍不确定。
目的: 本研究旨在评估从真实世界急诊科采集的手持智能手机视频中检测眼震的可行性。
方法: 分析了来自一个已发表的手持智能手机急性眩晕数据集的67段视频子集。一种基于显著特征的眼动追踪算法在帧间追踪稳定的眼部和眼周(面部)标志点。提取水平位移信号,并通过信号分析和视频验证识别眼震发作。
结果: 尽管存在真实世界挑战,包括光照变化、相机运动、图像不稳定和患者相关因素,仍成功从急性眩晕期采集的手持智能手机记录中提取出一致的眼动信号。视频中观察到的眼震模式在相应信号轨迹中得到准确反映,包括肉眼几乎难以辨认的极低振幅眼震。
结论: 我们的发现表明,使用标准低成本智能手机进行手持图像采集,可在真实世界急诊护理环境中捕获具有临床意义的眼动信息。这一原理验证为开发更具生态效度的可扩展、兼容远程医疗的急性眩晕评估工具奠定了基础。需要进一步研究以实现自动检测并在更大规模的前瞻性队列中验证性能。
英文摘要
BACKGROUND: Accurate identification of nystagmus is fundamental to the assessment of acute vertigo but remains challenging in emergency department (ED) settings. Although smartphone-based approaches have been proposed as scalable solutions, their feasibility under real-world acquisition conditions remains uncertain.
OBJECTIVE: This study aimed to evaluate the feasibility of detecting nystagmus from handheld smartphone videos acquired in a real-world ED.
METHODS: A subset of 67 videos from a published handheld smartphone-based acute vertigo dataset was analysed. A salient feature-based eye-tracking algorithm tracked stable ocular and periocular (facial) landmarks across frames. Horizontal displacement signals were extracted, and nystagmus episodes were identified through signal analysis and video verification.
RESULTS: Consistent eye-movement signals were successfully extracted from handheld smartphone recordings acquired during the acute phase of vertigo despite real-world challenges, including variable illumination, camera motion, image instability, and patient-related factors. Nystagmus patterns observed on video were accurately reflected in the corresponding signal traces, including very low-amplitude nystagmus that was barely discernible to the naked eye.
CONCLUSIONS: Our findings demonstrate that handheld image acquisition using standard, low-cost smartphones can capture clinically meaningful ocular motor information in real-world emergency care settings. This proof of principle lays the groundwork for the development of more ecologically valid scalable, telehealth-compatible tools for acute vertigo assessment. Further studies are needed to automate detection and validate performance in larger prospective cohorts.