目的: 空间分割是多种喉部成像模态客观分析的关键组成部分。手动分割是评估和训练自动化方法的当前金标准,但其本质上具有主观性且易受变异性影响。然而,对这种变异性的系统评估以及生成可靠真值的严谨方法仍然有限,因为大多数既往工作依赖于单一评估者。本研究以高速视频内窥镜(HSV)记录的空间分割作为测试案例,旨在(1)量化专家对声带边缘分割之间的差异并评估其可靠性,强调需要纳入多名评估者并报告评估者间和评估者内可靠性评分,以及(2)引入并评估一个用于生成具有亚像素分辨率的高可靠性真值的多阶段框架。
方法: 三名专家使用所提出的迭代三阶段框架对十二段HSV记录进行分割,该框架包括初始分割、高差异区域协调和共识审查。使用一种新的最大边缘变异性指标评估可靠性,并使用线性混合效应模型检验评估者、阶段和评估者数量对分割可靠性和真值不确定性的影响。
结果: 专家在初始分割中存在显著差异,效应量较大,证实了需要多名评估者。实验表明,增加评估者数量显著提高了真值可靠性并降低了不确定性,从一名到两名评估者的增益最大。所提出的框架显著提高了评估者内和评估者间可靠性,最显著的改善发生在共识阶段。所提出的最大边缘变异性为交并比(IOU)提供了一种稳健的替代方案,解决了IOU对声门面积大小的敏感性。
结论: 手动分割表现出相当大的变异性,强化了多评估者方案和明确报告可靠性评估的必要性。所提出的框架提供了一种系统、无偏的方法来生成具有亚像素分辨率的高可靠性真值,可 readily 应用于其他喉部成像模态(例如,视频频闪喉镜、窄带成像),在这些模态中,一致的边界描绘和明确的不确定性量化对于有效测量和评估至关重要。

英文摘要

OBJECTIVES: Spatial segmentation is a critical component of objective analysis across a wide range of laryngeal imaging modalities. Manual segmentation is the current gold standard for evaluating and training automated methods, which is inherently subjective and susceptible to variability. However, systematic evaluations of this variability and rigorous methods for generating reliable ground truth are limited, as most prior work has relied on a single rater. This study used spatial segmentation of high-speed videoendoscopy (HSV) recordings as a test case to (1) quantify differences among expert segmentations of the vocal fold edges and assess their reliability, highlighting the need to incorporate multiple raters and report inter- and intra-rater reliability scores, and (2) introduce and evaluate a multi-stage framework for generating highly reliable ground truth with sub-pixel resolution.
METHODS: Twelve HSV recordings were segmented by three experts using a proposed iterative, three-stage framework that included initial segmentation, reconciliation of high-discrepancy regions, and consensus review. Reliability was assessed using a novel metric of maximum edge variability, and linear mixed-effects models examined the effects of rater, stage, and number of raters on segmentation reliability and ground-truth uncertainty.
RESULTS: Experts differed substantially in initial segmentations with a large effect size, confirming the need for multiple raters. The experiments demonstrated that increasing the number of raters significantly improved ground-truth reliability and reduced uncertainty, with the largest gain from one to two raters. The proposed framework markedly enhanced both intra- and inter-rater reliability, with the most significant improvement occurring during the consensus stage. The proposed maximum edge variability provided a robust alternative to Intersection over Union (IOU), addressing IOU's sensitivity to glottal area size.
CONCLUSIONS: Manual segmentation demonstrated considerable variability, reinforcing the need for multi-rater protocols and explicit reporting of reliability evaluation. The proposed framework offers a systematic, unbiased approach for generating reliable ground truth with sub-pixel resolution that is readily applicable to other laryngeal imaging modalities (eg, videostroboscopy, Narrow Band Imaging) where consistent boundary delineation and explicit uncertainty quantification are essential for valid measurement and assessment.