耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

基于惯性测量单元的步伐分析用于前庭康复的客观评估

Inertial measurement unit-based gait analysis for objective assessment of vestibular rehabilitation.

临床研究耳科IF 3.2Q2

文献信息

中文摘要

背景: 急性前庭综合征(AVS)以突发性头晕、恶心、平衡受损和步态不稳为特征,严重影响正常日常活动。前庭康复可缓解该状况并促进恢复正常活动。本研究在起病时、6周康复计划结束后以及12周随访时进行的定时25英尺步行测试(T25FW)中,使用基于惯性测量单元(IMU)的步伐分析评估了30名AVS参与者的康复过程。54名健康对照也进行了一次T25FW。研究了基于五个下半身传感器或仅骨盆传感器的步态变量。临床变量:还记录了步行速度和眩晕症状量表简表(VSS-SF)眩晕-平衡子量表(VSS-V)。结果:在所有时间点之间观察到VSS-V的显著连续改善。此外,步行速度、步态轮廓评分(GPS)、骨盆GPS和步频从起病到康复期结束时下降,之后变化不显著。与对照组(1.26 m/s)相比,AVS组在基线(0.65 m/s,p < 0.0001)和12周时(1.13 m/s,p < 0.05)步行速度较慢。与对照组相比,基线时GPS、骨盆GPS、GPS不对称性和步频显著更高(分别为6.8° vs. 4.4°、3.6° vs. 2.6°和87步/分 vs. 118步/分,p < 0.0001)。与对照组相比,基线时GPS不对称性也更高(1.40步/分 vs. 0.80步/分,p < 0.05)。结论:通过基于IMU的步伐分析捕捉到了步态改善,即使仅使用单个传感器也是如此,这支持了使用单传感器和多传感器可穿戴系统进行康复评估的临床可行性。

英文摘要

Acute vestibular syndrome (AVS), defined by sudden onset of dizziness, nausea, impaired balance and gait instability, severely affects normal daily activities. Vestibular rehabilitation alleviates the condition and facilitates the return to normal activities. This study assessed the rehabilitation process of 30 participants with AVS using Inertial Measurement Unit (IMU)-based gait analysis during timed 25-ft walk tests (T25FW) conducted at onset, after a 6-week rehabilitation program, and at a 12-week follow-up. 54 healthy controls also performed the T25FW on one occasion. Gait variables based on either five lower body sensors or only the pelvis sensor were investigated. Clinical variables: walking speed and Vertigo Symptom Scale-Short Form (VSS-SF) vertigo-balance subscale (VSS-V) were also recorded. Significant successive improvements in VSS-V were observed between all timepoints. Furthermore, walking speed, Gait Profile Score (GPS), pelvis GPS, and cadence decreased from onset to the end of the rehabilitation period, after which changes were not significant. Walking speed was slower for the AVS group at baseline (0.65 m/s, p < 0.0001) and at 12 weeks (1.13 m/s, p < 0.05) compared to controls (1.26 m/s). GPS, pelvis GPS, GPS asymmetry, and cadence were significantly greater compared to controls at baseline (6.8° vs. 4.4°, 3.6° vs. 2.6°, and 87 steps/min vs. 118 steps/min, respectively, p < 0.0001). GPS asymmetry was also higher at baseline compared to controls (1.40 steps/min vs. 0.80 steps/min, p < 0.05). In conclusion, gait improvement was captured via IMU-based gait analysis, even when using a single sensor, supporting the clinical feasibility of using both single- and multi-sensor wearable systems for rehabilitation assessment.