儿童同期与序贯双侧人工耳蜗植入后的听力学与功能结局:一项比较性队列研究
Audiological and functional outcomes following simultaneous versus sequential bilateral cochlear implantation in children: A comparative cohort study.
文献信息
| PMID | 43008340 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Lokanath Sahoo |
| 作者单位 | Senior Audiologist and Speech-Language Pathologist, Department of ENT, Command Hospital (Southern Command), Pune, India. Electronic address: lokanath.aslp@gmail.com. |
| 期刊 | International journal of pediatric otorhinolaryngology |
| SCI 分区 | Q2 |
| IF | 1.7 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 耳科 |
中文摘要
目的: 比较儿童同期双侧人工耳蜗植入(SBLI)与早期序贯双侧人工耳蜗植入(SQLI)后的听力学、言语及功能性听觉结局,并探讨序贯植入儿童中植入间隔与结局之间的关系。
方法: 本比较性队列研究纳入50例双侧重度至极重度感音神经性听力损失儿童,其中接受SBLI者34例,接受SQLI者16例。所有儿童首次人工耳蜗植入均在5岁前完成;SQLI组中,第二侧植入在首次植入后24个月内完成。所有儿童在标准化结局评估前均完成2年结构化听觉-言语治疗(AVT)。主要结局为助听听阈纯音平均(PTA)和言语感知;次要结局包括CAP、SIR、MAIS、MUSS、LIP和SSQ。
结果: SBLI与SQLI的助听PTA(32.03 ± 4.17 vs 33.50 ± 3.58 dB HL;p = 0.208)和言语感知(82.74 ± 6.79% vs 82.56 ± 6.79%;p = 0.934)相当。CAP、MAIS、MUSS、LIP和SSQ未见显著组间差异。SBLI后SIR更高[中位数4(IQR 3-5)vs 3(IQR 3-4);p = 0.009]。在调整首次植入年龄和每日人工耳蜗使用时间后,SBLI仍与更高的SIR分级相关(校正OR 5.15;95% CI 1.53-17.32;p = 0.008)。
结论: SBLI与早期SQLI在助听听阈、言语感知及大多数功能性听觉结局方面相当。SBLI与更高的言语清晰度相关;然而,较宽的置信区间和潜在残余混杂因素提示应谨慎解读,并需在更大队列中加以确认。
英文摘要
OBJECTIVE: To compare audiological, speech, and functional auditory outcomes following simultaneous bilateral cochlear implantation (SBLI) and early sequential bilateral cochlear implantation (SQLI) in children, and to explore the relationship between inter-implant interval and outcomes in sequentially implanted children.
METHODS: This comparative cohort study included 50 children with bilateral severe-to-profound sensorineural hearing loss who underwent SBLI (n = 34) or SQLI (n = 16). First cochlear implantation was performed before 5 years of age in all children; in the SQLI group, the second implant was placed within 24 months of the first. All children completed 2 years of structured auditory-verbal therapy (AVT) before standardized outcome assessment. Primary outcomes were aided pure-tone average (PTA) and speech perception; secondary outcomes included CAP, SIR, MAIS, MUSS, LIP, and SSQ.
RESULTS: Aided PTA (32.03 ± 4.17 vs 33.50 ± 3.58 dB HL; p = 0.208) and speech perception (82.74 ± 6.79% vs 82.56 ± 6.79%; p = 0.934) were comparable between SBLI and SQLI. CAP, MAIS, MUSS, LIP, and SSQ showed no significant between-group differences. SIR was higher following SBLI [median 4 (IQR 3-5) vs 3 (IQR 3-4); p = 0.009]. After adjustment for age at first implantation and daily cochlear implant use, SBLI remained associated with a higher SIR category (adjusted OR 5.15; 95% CI 1.53-17.32; p = 0.008).
CONCLUSION: SBLI and early SQLI achieved comparable aided hearing, speech perception, and most functional auditory outcomes. SBLI was associated with higher speech intelligibility; however, the wide confidence interval and potential residual confounding warrant cautious interpretation and confirmation in larger cohorts.