耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

前庭神经鞘瘤中的批量转录组推断对估计细胞组成敏感:跨队列分析与单细胞谱系注释

Bulk Transcriptomic Inference in Vestibular Schwannoma is Sensitive to Estimated Cell Composition: Cross-Cohort Analysis and Single-Cell Lineage Annotation.

基础研究耳科IF 2.9Q3

文献信息

中文摘要

背景: 前庭神经鞘瘤(VS)与神经之间的批量转录组差异既反映基因表达差异,也反映组织组成差异。我们评估了GSE39645(31例VS;9例神经/Schwann细胞对照)中的组成敏感性,将固定的346基因集与GSE108524(27例VS,包括10例散发性和17例NF2相关病例;4例神经对照)进行比较,并使用GSE230375进行去卷积和供者水平伪批量分析。仅肿瘤的GSE216783提供了第二个参考,而GSE250061支持描述性宽谱系注释。方法:在预先设定的组加批次模型及五个MuSiC组成主成分中,1,410个基线差异表达基因中有326个同时保留错误发现率<0.05和绝对log2倍数变化>1的阈值;1,084个至少丢失一个阈值,包括117个方向反转,405个仅为校正后阈值判定。主要设计的组方差膨胀因子(VIF)为8.747;500次样本分层bootstrap抽样中有303次超过VIF 10,但仍保持满秩并被保留。在固定的346个基因中,所有VS的方向一致性为93.4%,散发病例为94.5%,NF2相关病例为93.6%。所有VS的Pearson相关系数为0.883(95%百分位区间0.834-0.897);区间以固定参考、注释和基因集为条件。结果:一项20+20+20重复模拟显示,条件性β为零的仅组成判定更少,但仅表达标准误和均方根系数误差更大,在4/20估计MuSiC和3/20 oracle强场景拟合中出现VIF>10;所有拟合均保持满秩。结论:这些分析量化了模型敏感性;宽谱系分配和模拟均未确立机制、生物标志物或治疗靶点。

英文摘要

Bulk transcriptomic differences between vestibular schwannoma (VS) and nerve reflect both gene-expression differences and tissue composition. We evaluated composition sensitivity in GSE39645 (31 VS; nine nerve/Schwann-cell controls), compared a fixed 346-gene set with GSE108524 (27 VS, including 10 sporadic and 17 NF2-related cases; four nerve controls), and used GSE230375 for deconvolution and donor-level pseudobulk. Tumor-only GSE216783 supplied a second reference, while GSE250061 supported descriptive broad-lineage annotation. In the prespecified group-plus-batch model with five MuSiC composition principal components, 326 of 1,410 baseline differentially expressed genes retained both false-discovery rate < 0.05 and absolute log2 fold change > 1 thresholds; 1,084 lost at least one threshold, including 117 with reversed direction, and 405 were adjusted-only threshold calls. The primary design had group variance-inflation factor (VIF) 8.747; 303/500 sample-stratified bootstrap draws exceeded VIF 10 but remained full rank and were retained. Across the fixed 346 genes, direction concordance was 93.4% for all VS, 94.5% for sporadic cases and 93.6% for NF2-related cases. All-VS Pearson correlation was 0.883 (95% percentile interval 0.834-0.897); intervals were conditional on fixed references, annotations and gene set. A 20 + 20 + 20-repeat simulation showed fewer conditional beta-zero composition-only calls but greater expression-only standard errors and root-mean-square coefficient error, with VIF > 10 in 4/20 estimated-MuSiC and 3/20 oracle strong-scenario fits; all fits remained full rank. These analyses quantify model sensitivity; neither broad-lineage assignment nor simulation establishes mechanism, biomarkers or therapeutic targets.