FLIP测量可预测贲门失弛缓症患者单次EsoFLIP扩张后的短期结局。
FLIP Measurements Predict Short-Term Outcomes After Singular EsoFLIP Dilation in Patients With Achalasia.
文献信息
| PMID | 43004889 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Johann Stuby |
| 作者单位 | Department of Gastroenterology and Hepatology, Zurich University Hospital, Zurich, Switzerland. |
| 期刊 | Neurogastroenterology and motility |
| SCI 分区 | Q2 |
| IF | 3.8 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 咽喉科 |
中文摘要
背景: FLIP可在扩张过程中实时测量食管胃连接处(EGJ)的尺寸和压力。虽然FLIP指标可预测气囊扩张、POEM和肌切开术后的结局,但其在EsoFLIP扩张后的预测价值仍不清楚。本研究旨在确定可预测贲门失弛缓症患者单次EsoFLIP扩张后短期结局的FLIP测量指标。
方法: 分析2017—2025年接受单次EsoFLIP扩张的初治患者。在扩张前和扩张后,于70 mL时测量EGJ直径(EGJ-Dia)和横截面积(EGJ-CSA),于60 mL时测量扩张性指数(EGJ-DI)和球囊压力(EGJ-BP)。主要结局为4周时短期症状应答优异(Eckardt评分≤1)。
结果: 共纳入79例患者(女性38%,中位年龄52岁;贲门失弛缓症1型8%、2型87%、3型5%)。症状应答率为81%(ES≤3或Δ≥3),46%达到ES≤1;客观应答率为67%。中位ES从6(IQR 4-7)降至2(IQR 0-4)。中位EGJ-Dia从10 mm增至17 mm,EGJ-CSA从72 mm2增至220 mm2,EGJ-DI从1.4 mm2/mmHg增至5.8 mm2/mmHg,而EGJ-BP从31 mmHg降至24 mmHg(均p<0.001)。在51例数据完整的患者中,ΔEGJ-Dia70(AUROC 0.77,切点≥6.3 mm)和ΔEGJ-CSA70(AUROC 0.75,切点≥129.3 mm2)的预测性能最高。ΔEGJ-DI60表现中等(AUROC 0.65),而ΔBP60无判别能力(AUROC 0.45)。
结论: FLIP指标的差值,尤其是ΔEGJ-Dia和ΔEGJ-CSA,可预测优异的短期症状应答。这些发现表明,术中FLIP测压法可能有助于评估EsoFLIP扩张过程中的治疗充分性。
英文摘要
BACKGROUND: FLIP enables real-time measurement of esophagogastric junction (EGJ) dimensions and pressures during dilation. While FLIP metrics predict outcomes after pneumatic dilation, POEM, and myotomy, their predictive value following EsoFLIP dilation remains unknown. This study identified FLIP measurements predicting short-term outcomes after EsoFLIP dilation in patients with achalasia.
METHODS: Treatment-naïve patients undergoing singular EsoFLIP dilation (2017-2025) were analyzed. EGJ diameter (EGJ-Dia) and cross-sectional area (EGJ-CSA) were measured at 70 mL, distensibility index (EGJ-DI) and balloon pressure (EGJ-BP) at 60 mL, pre- and post-dilation. Primary outcome was excellent short-term symptomatic response at 4 weeks (Eckardt score ≤ 1).
RESULTS: Seventy-nine patients (38% female, median age 52 years, achalasia type 1: 8%, type 2: 87%, type 3: 5%) were included. Symptomatic response was 81% (ES ≤ 3 or Δ ≥ 3) and 46% (ES ≤ 1); objective response 67%. Median ES decreased from 6 (IQR 4-7) to 2 (IQR 0-4). Median EGJ-Dia increased from 10 mm to 17 mm, EGJ-CSA from 72 mm2 to 220 mm2, and EGJ-DI from 1.4 mm2/mmHg to 5.8 mm2/mmHg, while EGJ-BP decreased from 31 mmHg to 24 mmHg (all p < 0.001). Among 51 patients with complete data, ΔEGJ-Dia70 (AUROC 0.77, cut-off ≥ 6.3 mm) and ΔEGJ-CSA70 (AUROC 0.75, cut-off ≥ 129.3 mm2) showed highest predictive performance. ΔEGJ-DI60 showed moderate performance (AUROC 0.65), while ΔBP60 was non-discriminative (AUROC 0.45).
CONCLUSION: Delta values in FLIP metrics, particularly ΔEGJ-Dia and ΔEGJ-CSA, predicted excellent short-term symptomatic response. These findings indicate that intra-procedural FLIP panometry may help assess treatment adequacy during EsoFLIP dilation.