中文摘要

目的: 即使使用视频喉镜,预测困难插管仍然具有挑战性。视频喉镜(VL)在插管过程中显示喉部。改良Cormack-Lehane(CL)分级用于评估喉部可见度,但不同观察者之间可能存在差异。深度学习利用神经网络对气道图像进行客观、实时的评估。我们旨在评估一种基于YOLOv8的目标检测模型,用于在择期手术患者中从VL图像自动进行改良CL分级分类。
方法: 在这项前瞻性观察性研究中,我们使用来自151例择期手术患者的346张VL图像开发了一个深度学习模型。两名麻醉科医生根据改良CL系统对图像进行分类,并使用Cohen kappa和加权kappa分析观察者间一致性。我们将数据分为训练集(80%)、验证集(10%)和测试集(10%),并通过Albumentations增强校正不平衡。我们使用敏感性、特异性和平均平均精度及95%置信区间(CI)评估模型结果,并在未纳入训练集的60张图像上验证模型。
结果: 观察者间一致性范围为中等(Cohen kappa = 0.59;95% CI,0.53至0.66)至良好(加权kappa = 0.79;95% CI,0.75至0.84)。在测试集中,总体召回率为0.87,特异性为0.83。在困难插管分级中,CL 2b级的召回率和特异性分别为0.79(95% CI,0.52至0.92)和0.93(95% CI,0.78至0.98),CL 3级分别为0.60和1.00。在外部验证数据集(n = 60)中,模型总体准确率为0.767,对临床相关CL 2b和3级的识别率为0.925。
结论: 基于YOLOv8的模型在改良CL分级分类方面表现出良好性能,尤其是对临床相关的困难视野(CL 2b-3级)。然而,宽泛的CI和有限的外部验证表明存在不确定性。该模型可被视为辅助工具而非独立决策系统,并需要在更大规模的多中心数据集中进一步验证。

英文摘要

PURPOSE: Predicting difficult intubation is still challenging, even with videolaryngoscopy. Videolaryngoscopy (VL) shows the larynx during intubation. The modified Cormack-Lehane (CL) classification grades laryngeal visibility but can vary between observers. Deep learning uses neural networks for objective, real-time airway image evaluation. We aimed to evaluate a YOLOv8-based model for object detection to automate modified CL grade classification from VL images in patients undergoing elective surgery.
METHODS: In this prospective observational study, we developed a deep learning model using 346 VL images from 151 patients undergoing elective surgery. Two anesthesiologists classified images according to the modified CL system, and interobserver agreement was analysed using Cohen's kappa and weighted kappa. We split the data into training (80%), validation (10%), and test (10%) sets, with imbalance corrected via Albumentations augmentation. We evaluated the model results using sensitivity, specificity, and mean average precision with a 95% confidence interval (CI) and validated the model on 60 images not included in the training set.
RESULTS: Interobserver agreement ranged from moderate (Cohen's kappa = 0.59; 95% CI, 0.53 to 0.66) to good (weighted kappa = 0.79; 95% CI, 0.75 to 0.84). In the test set, the overall recall rate was 0.87, and the specificity was 0.83. In the difficult intubation grades, recall and specificity were observed to be 0.79 (95% CI, 0.52 to 0.92) and 0.93 (95% CI, 0.78 to 0.98), respectively, for CL grade 2b, and 0.60 and 1.00, respectively, for CL grade 3. In the external validation data set (n = 60), the model achieved an overall accuracy of 0.767 with a recognition rate of 0.925 for clinically relevant CL grades 2b and 3.
CONCLUSIONS: The YOLOv8-based model showed promising performance in classifying modified CL grades, particularly for clinically relevant difficult views (CL grades 2b-3). Nevertheless, wide CIs and limited external validation indicate uncertainty. The model may be considered an auxiliary tool rather than an independent decision system and requires further validation in larger, multicentre data sets.