耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

i-gel与经典喉罩在不同头位下对≥75岁患者的临床性能:一项前瞻性随机研究

Clinical performance of i-gel and classic laryngeal mask airway in different head positions in patients aged ≥75 years: A prospective randomized study.

临床研究咽喉科IF 1.8Q3

文献信息

中文摘要

目的: 声门上气道装置是全麻下气管插管的替代方案。然而,其在老年患者中的性能仍研究不足,尤其是在不同头位下。方法:这项前瞻性随机对照研究纳入120例接受择期泌尿外科手术的≥75岁患者。根据置入时的装置类型和头位,患者被随机分配到四组:(a) i-gel配合中立头位;(b) i-gel配合右转头位;(c) 经典喉罩配合中立头位;(d) 经典喉罩配合右转头位。主要结局为置入时间。次要结局包括置入尝试次数、口咽漏气压及围术期变量,这些均在装置置入成功的患者中评估。结果:总体置入成功率为94.2%(113/120)。与经典喉罩相比,i-gel的置入时间显著更短,口咽漏气压更高(均p=0.001)。双因素析因分析显示,装置类型显著影响置入时间和口咽漏气压,而头位及装置与头位的交互作用无显著影响。在置入尝试次数、纤维光学视野评分、气道峰压、恢复时间、血流动力学变量或围术期及术后并发症方面,未观察到显著差异。结论:在接受择期手术的≥75岁患者中,与经典喉罩相比,i-gel的置入时间更短,口咽漏气压更高。头位未显著影响置入时间、口咽漏气压或气道峰压。这些发现提示,气道装置的选择对声门上气道性能的影响大于头位,而i-gel在特定临床环境中可能提供实用优势。试验注册:ClinicalTrials.gov(https://clinicaltrials.gov),标识符:NCT07027293,于2025年5月27日注册。

英文摘要

ObjectiveSupraglottic airway devices are alternatives to endotracheal intubation under general anesthesia. However, their performance in older patients remains understudied, particularly in different head positions.MethodsThis prospective randomized controlled study included 120 patients aged ≥75 years undergoing elective urologic surgery. Patients were randomly allocated into four groups based on the device type and head position during insertion: (a) i-gel with neutral head position; (b) i-gel with right head rotation; (c) classic laryngeal mask airway with neutral head position; and (d) classic laryngeal mask airway with right head rotation. The primary outcome was the insertion time. Secondary outcomes included insertion attempts, oropharyngeal leak pressure, and perioperative variables, which were assessed in patients with successful device placement.ResultsThe overall insertion success rate was 94.2% (113/120). The i-gel was associated with a significantly shorter insertion time and higher oropharyngeal leak pressure than the classic laryngeal mask airway (both p = 0.001). Two-way factorial analysis revealed that device type significantly influenced insertion time and oropharyngeal leak pressure, whereas head position and device-by-head position interaction exerted no significant effects. No significant differences were observed in the number of insertion attempts, fiberoptic view scores, peak airway pressure, recovery times, hemodynamic variables, or perioperative and postoperative complications.ConclusionsIn patients aged ≥75 years undergoing elective surgery, the i-gel was associated with a shorter insertion time and higher oropharyngeal leak pressure than the classic laryngeal mask airway. Head position did not significantly influence insertion time, oropharyngeal leak pressure, or peak airway pressure. These findings suggest that airway device selection exerts a greater impact on supraglottic airway performance than head position, whereas the i-gel may offer practical advantages in selected clinical settings.Trial registration: ClinicalTrials.gov (https://clinicaltrials.gov), Identifier: NCT07027293, registered on 27 May 2025.