耳鼻喉科Pubmed文献追踪每日 14:00 同步
← 返回全部文献
Article record

基于HRCT的外耳道三维形态学分析用于经耳道手术规划与导航

HRCT-Based Three-Dimensional Morphometric Analysis of the External Auditory Canal for Transcanal Surgical Planning and Navigation.

临床研究耳科IF 1.8Q3

文献信息

中文摘要

目的: 通过高分辨率计算机断层扫描(HRCT)重建三维(3D)中心线并量化关键解剖参数(包括曲率指数、体积、表面积和耳道尺寸),为外耳道(EAC)内连续体机器人导航建立初步的路径规划框架。
方法: 对75名成人(103耳;52只男性耳和51只女性耳;平均年龄46.55 ± 12.37岁)进行回顾性研究,这些受试者接受了层厚0.67 mm的颞骨HRCT检查。使用3D Slicer软件进行外耳道的三维重建和中心线提取。测量形态学参数,包括外耳道长度、平均半径、体积、表面积和曲率指数。根据数据分布采用参数或非参数检验进行统计分析。
结果: 外耳道平均长度为29.92 ± 2.69 mm,平均半径为3.29 ± 0.36 mm,体积为1020.34 ± 207.64 mm3,表面积为688.61 ± 97.81 mm2,曲率指数为1.07 ± 0.04。男性参与者的外耳道尺寸显著大于女性参与者,包括更大的体积(1082.79 vs. 956.66 mm3)、表面积(725.12 vs. 651.38 mm2)和长度(30.79 vs. 29.04 mm;所有P < 0.05)。右侧外耳道体积(1028.37 vs. 954.30 mm3)和半径(3.32 vs. 3.20 mm)大于左侧外耳道(P < 0.05)。外耳道体积与半径呈强正相关(r = 0.904),与长度呈中度负相关(r = -0.341),提示两种解剖表型:以较长长度和较小半径为特征的“细长型”耳道,以及以较短长度和较大半径为特征的“粗壮型”耳道。
结论: 本研究基于3D HRCT重建获得的中心线坐标,提出了外耳道内连续体机器人导航的初步解剖学框架。定量形态学参数(包括曲率指数和耳道半径)可能为柔性机器人系统的设计、验证和轨迹规划提供重要参考数据。所提出的方法还可能支持未来个体化经耳道手术导航和微创耳科干预的发展。

英文摘要

OBJECTIVE: To establish a preliminary pathway-planning framework for continuum robotic navigation within the external auditory canal (EAC) by reconstructing the three-dimensional (3D) centerline and quantifying key anatomical parameters, including curvature index, volume, surface area, and canal dimensions, using high-resolution computed tomography (HRCT).
METHODS: A retrospective study was conducted in 75 adults (103 ears; 52 male and 51 female ears; mean age, 46.55 ± 12.37 years) who underwent temporal bone HRCT with a slice thickness of 0.67 mm. Three-dimensional reconstruction and centerline extraction of the EAC were performed using 3D Slicer software. Morphological parameters, including EAC length, mean radius, volume, surface area, and curvature index, were measured. Statistical analyses were performed using parametric or non-parametric tests according to data distribution.
RESULTS: The mean EAC length was 29.92 ± 2.69 mm, mean radius was 3.29 ± 0.36 mm, volume was 1020.34 ± 207.64 mm3, surface area was 688.61 ± 97.81 mm2, and curvature index was 1.07 ± 0.04. Male participants exhibited significantly larger EAC dimensions than female participants, including greater volume (1082.79 vs. 956.66 mm3), surface area (725.12 vs. 651.38 mm2), and length (30.79 vs. 29.04 mm; all P < 0.05). Right-sided EACs demonstrated larger volume (1028.37 vs. 954.30 mm3) and greater radius (3.32 vs. 3.20 mm) than left-sided EACs (P < 0.05). EAC volume showed a strong positive correlation with radius (r = 0.904) and a moderate negative correlation with length (r = -0.341), suggesting two anatomical phenotypes: "slender" canals characterized by greater length and smaller radius, and "robust" canals characterized by shorter length and larger radius.
CONCLUSION: This study presents a preliminary anatomical framework for continuum robotic navigation within the EAC based on centerline coordinates derived from 3D HRCT reconstruction. Quantitative morphometric parameters, including curvature index and canal radius, may provide important reference data for the design, validation, and trajectory planning of flexible robotic systems. The proposed methodology may also support future development of individualized transcanal surgical navigation and minimally invasive otologic interventions.