鼻整形术中导航截骨术的准确性:一项尸体分析
Accuracy of Navigated Osteotomies in Rhinoplasty: A Cadaveric Analysis.
文献信息
| PMID | 42951306 |
|---|---|
| 原文 | 在 PubMed 查看原文 ↗ |
| 发表日期 | 2026 |
| 作者 | Tom A Lauwers |
| 作者单位 | Department of Otorhinolaryngology Head and Neck Surgery, University Hospital Zürich, University of Zürich, Zürich, Switzerland. |
| 期刊 | The Laryngoscope |
| SCI 分区 | Q2 |
| IF | 2.3 |
| 研究类型 | 临床研究 · 临床 |
| 所属专科 | 鼻科 |
中文摘要
背景: 导航引导的鼻整形术允许对截骨术进行详细规划和引导。我们旨在研究使用CT导航系统是否可行,以及是否能够在特定位置执行更精确的截骨术,从而提高准确性。
方法: 在九个尸体头部上进行了双侧电磁导航鼻上颌缝截骨术(n = 18),采用经鼻(n = 4)或经皮(n = 14)技术。解剖后,我们在(n = 5)个标本上手动评估了截骨与骨缝之间的距离。此外,在基线和术后进行了锥形束计算机断层扫描,以计算截骨与骨缝线之间的平均距离和中位距离。
结果: 手动测量的预期与实际截骨之间的平均距离为0.75 mm(95%置信区间[CI] 0.06-1.44 mm),中位距离为0.00 mm(四分位距[IQR] 0.00-1.19 mm)。在10次手术中的6次,截骨按计划创建,没有可见偏差。总体而言,在影像上,导航引导的截骨术与骨缝的平均偏差为1.50 mm(95% CI 0.87-2.12 mm),标准差(SD)为1.35 mm。中位距离为0.73 mm(IQR 0.59-2.61 mm)。经鼻和经皮截骨术的准确性相似(p = 0.63)。
结论: 导航引导的截骨术显示出良好的可行性,经皮和经鼻技术均具有临床有用的亚毫米级准确性。描述了一种用于术后结果分析的模型,具有临床有用的准确性,但不如直接观察那么高。
证据等级: 不适用。
英文摘要
BACKGROUND: Navigation guided rhinoplasty allows detailed planning and guidance of osteotomies. We aimed to investigate whether the use of a CT navigation system is feasible and capable of performing more precise osteotomies at specific locations, thus improving accuracy.
METHODS: Bilateral electromagnetic-navigated osteotomies (n = 18) of the nasomaxillary suture were performed on nine cadaver heads, using a transnasal (n = 4) or percutaneous (n = 14) technique. After dissection, we manually assessed the distance between the osteotomy and the suture on (n = 5) specimens. Additionally, at baseline and postoperatively, a cone beam computed tomography was performed to calculate the mean and median distance between the osteotomy and the suture line.
RESULTS: The manually measured mean distance from intended to actual osteotomy was 0.75 mm (mm) (95% confidence interval [CI] 0.06-1.44 mm) with a median distance of 0.00 mm (interquartile range [IQR] 0.00-1.19 mm). In 6 of 10 procedures, the osteotomy was created according to plan with no visible deviation. Overall, on imaging, the navigation-guided osteotomies deviated from the suture by an average of 1.50 mm (95% CI 0.87-2.12 mm) with a standard deviation (SD) of 1.35 mm. The median distance was 0.73 mm (IQR 0.59-2.61 mm). The accuracies of transnasal and percutaneous osteotomies were similar (p = 0.63).
CONCLUSION: Navigation-guided osteotomies demonstrated good feasibility with clinically useful sub-millimeter accuracy for both percutaneous and transnasal techniques. A model for postoperative outcome analysis is described with clinically useful accuracy, though not as high as direct observation.
LEVEL OF EVIDENCE: N/A.