电极-蜗轴距离作为人工耳蜗性能的决定因素:系统综述与荟萃分析

Electrode-Modiolar Distance as a Determinant of Cochlear Implant Performance: A Systematic Review and Meta-Analysis.

综述 Meta耳科IF 2Q2

文献信息

中文摘要

目的: 量化电极-蜗轴距离(EMD)与人工耳蜗(CI)在言语/感知、电生理和编程结局方面的关系,并描述EMD的剂量-反应效应。
方法: 按照PRISMA指南对PubMed/MEDLINE、Embase、Scopus、Web of Science和Cochrane CENTRAL进行了系统检索。纳入报告CT或CBCT衍生的EMD及CI结局的人体研究。效应量转换为比值比(OR),并使用随机效应模型进行合并。进行了亚组、敏感性和剂量-反应分析。使用I2评估异质性,并使用漏斗图和Egger检验评估发表偏倚。
结果: 共纳入21项研究,约1181只植入耳。较小的EMD与有利CI结局的显著更高几率相关(合并OR=2.16,95% CI:1.89-2.45;p<0.001;I2=0%)。在言语/感知结局(OR=2.23)、电生理指标(敏感性调整后OR=2.80)和编程参数(OR=1.72)方面观察到一致效应。剂量-反应模型显示单调梯度,EMD每增加1 mm,有利结局的几率降低20%-30%(每mm OR≈0.72;p<0.001)。未检测到显著发表偏倚(Egger p=0.056)。
结论: 电极-蜗轴邻近度是CI性能强而一致的决定因素,具有明确的剂量-反应关系,支持其作为临床可操作的影像生物标志物,用于优化电极选择、手术策略和个体化编程。
试验注册: PROSPERO:CRD420261380236。

英文摘要

OBJECTIVE: To quantify the relationship between electrode-modiolar distance (EMD) and cochlear implant (CI) performance across speech/perceptual, electrophysiological and programming outcomes and to characterize the dose-response effect of EMD.
METHODS: A systematic search of PubMed/MEDLINE, Embase, Scopus, Web of Science and Cochrane CENTRAL was conducted in accordance with PRISMA guidelines. Human studies reporting CT- or CBCT-derived EMD and CI outcomes were included. Effect sizes were transformed to odds ratios (ORs) and pooled using random-effects models. Subgroup, sensitivity and dose-response analyses were performed. Heterogeneity was assessed using I2, and publication bias was evaluated using funnel plots and Egger's test.
RESULTS: Twenty-one studies comprising approximately 1181 implanted ears were included. Reduced EMD was associated with significantly higher odds of favourable CI outcomes (pooled OR = 2.16, 95% CI: 1.89-2.45; p < 0.001; I2 = 0%). Consistent effects were observed for speech/perceptual outcomes (OR = 2.23), electrophysiological measures (OR = 2.80 after sensitivity adjustment) and programming parameters (OR = 1.72). Dose-response modelling demonstrated a monotonic gradient, with each 1 mm increase in EMD associated with a 20%-30% reduction in the odds of favourable outcomes (OR per mm ≈0.72; p < 0.001). No significant publication bias was detected (Egger's p = 0.056).
CONCLUSION: Electrode-modiolar proximity is a strong and consistent determinant of CI performance with a clear dose-response relationship, supporting its role as a clinically actionable imaging biomarker for optimizing electrode selection, surgical strategy and individualized programming.
TRIAL REGISTRATION: PROSPERO: CRD420261380236.