胆脂瘤听骨链重建术后的听力结局:自体与假体重建的回顾性比较。

Hearing outcomes after ossiculoplasty for cholesteatoma: A retrospective comparison of autologous versus prosthetic reconstructions.

临床研究耳科IF 2.3Q1

文献信息

中文摘要

目的: 比较胆脂瘤患者中自体与假体听骨链重建术后的听力结局。
主要终点: 使用自体材料(软骨或砧骨间置)或部分及全钛假体进行听骨链重建后,纯音平均气骨导差(ΔPTA-ABG)的术后变化。
方法: 分析2015年至2023年间在一家法国大学医院因慢性中耳炎伴胆脂瘤(COM-C)接受鼓室成形术联合听骨链重建术的312例成年患者,分为两组:自体重建组(n=192)和假体重建组(n=120)。ΔPTA-ABG(500-3000 Hz)为主要结局,次要终点包括250-4000 Hz的气导阈值。收集术前和术后(≥6个月)的听力学数据。采用单因素和多因素线性回归分析,并校正既往耳部手术、手术入路和手术时机等混杂因素。
结果: 自体重建组(3.3±11.6 dB)与假体重建组(4.6±13.0 dB)之间的ΔPTA-ABG无显著差异(p=0.37)。频率特异性分析显示,仅在250 Hz处ΔABG存在显著差异(p=0.02)。假体重建在250 Hz(p=0.04)、500 Hz(p=0.02)和1000 Hz(p=0.05)的气导阈值改善更大,而在更高频率未观察到差异。假体组术前阈值更差(p=0.009)。多因素分析证实ΔPTA-ABG变异不存在其他预测因素。
结论: 尽管假体组基线疾病更为晚期,自体与假体听骨链重建术与相当的气骨导差改善相关。鉴于该回顾性设计固有的残余混杂,这些发现应解释为改善程度相当,而非重建材料之间等效性的证明。

英文摘要

OBJECTIVE: To compare hearing outcomes between autologous and prosthetic ossiculoplasty in patients with cholesteatoma.
PRIMARY ENDPOINT: Postoperative change in pure-tone average air-bone gap (ΔPTA-ABG) following ossicular chain reconstruction using either autologous materials (cartilage or incus interposition) or partial and total titanium prostheses.
METHODS: Analyze of 312 adult patients who underwent tympanoplasty with ossiculoplasty for COM-C between 2015 and 2023 at a French university hospital, divided into two groups: autologous reconstruction (n = 192) and prosthetic reconstruction (n = 120). ΔPTA-ABG (500-3000 Hz) was the primary outcome, with secondary endpoints including air conduction thresholds at 250-4000 Hz. Audiometric data were collected pre- and postoperatively (≥ 6 months). Univariate and multivariate linear regression analyses adjusted for confounders such as prior ear surgery, surgical approach, and operative timing.
RESULTS: No significant difference in ΔPTA-ABG was found between autologous (3.3 ± 11.6 dB) and prosthetic (4.6 ± 13.0 dB) reconstructions (p = 0.37). Frequency-specific analysis showed a significant ΔABG difference only at 250 Hz (p = 0.02). Prosthetic reconstruction demonstrated greater improvement in air conduction thresholds at 250 Hz (p = 0.04), 500 Hz (p = 0.02), and 1000 Hz (p = 0.05), while no differences were observed at higher frequencies. Preoperative thresholds were worse in the prosthetic group (p = 0.009). Multivariate analysis confirmed the absence of additional predictors of ΔPTA-ABG variance.
CONCLUSION: Despite more advanced baseline disease in the prosthetic group, autologous and prosthetic ossiculoplasty were associated with comparable air-bone gap improvement. Given the residual confounding inherent to this retrospective design, these findings should be interpreted as comparable improvement rather than as proof of equivalence between reconstruction materials.